Laserfiche WebLink
. 45 DOWN PIPE-INDEPENDENTLY SUPPORTED-(EXTERNAL ONLY) <br /> 451 Down pipes are shipped loose and have been cut to size to meet customer specifications All <br /> down pipes shall be supported at 42 in maximum intervals with the support clamps provided <br /> 452 Assemble the piping loosely using Figure 4 5, the guidelines detailed below,and the customer <br /> approved tank drawing to ensure all parts are present and out to meet the customer's requirements <br /> Mark the strut post base on the concrete when in proper position Install 2 ea 3/8"adhesive anchors <br /> and bolt base into position As soon as all parts have been checked,assemble the parts with solvent <br /> weld cement and/or threaded connections as shown in Figure 4 5. <br /> 453 Assemble and install support structures as shown in Figure 4 5 Make sure the support clamps are <br /> spaced evenly Locate the strut catchers and twist 900 to lock in place Install the clamps to the strut <br /> catchers with the#10 screws provided Clamps 3 in and larger require 2 ea strut catchers, #10 <br /> screws and#10 washers The pipe will click into position in the clamps Make sure all clamps have <br /> clicked to full engagement and are tight. Assemble and install piping as per the customer approval <br /> TANK FITTING (CAN BE <br /> TFREAOM OR SOCKET <br /> COWIECTIi7�1) <br /> SLIPPU <br /> aAMP A EXTERNAL <br /> CLAMi7 AND Pit MUPIPE <br /> STRUT RSSi19 E3 <br /> CATCi R <br /> STRUT <br /> STRUT <br /> POST <br /> BASE <br /> Figure 4.5 <br /> drawing Seal all threaded pipe connections with Teflon"pipe sealant and connect solvent weld <br /> sockets with solvent cement <br /> 46 FLEXIBLE SIGHT LEVEL GAGES <br /> 461 Sight level gage assemblies are shipped loose and have been cut to size to meet customer <br /> specifications Sight gages may be ordered with either no valve, 1,2,or 3 valves Please refer <br /> to the customer approved drawing to determine the number of valves required <br /> 462 Using the assembly drawings shown in Figure 4 6, verify that all parts are present and assemble <br /> the unit per the appropriate drawing Seal all threaded pipe connections with Teflon•pipe sealant <br /> Gallonage decals may be purchased as separate items and customer applied to the tank to assist <br /> in indication of tank gallonage NOTE- Gallonage decals are not available for all tank sizes <br /> 47 REVERSE LEVEL SIGHT GAGE <br /> 471 The component parts (except the rope) have been out to meet Sit and customer specifications <br /> The sight gage shall be supported at 5 ft maximum intervals to the liquid holding tank with the <br /> support structures provided <br /> 472 Assemble the piping loosely using Figure 4 7,the guidelines detailed below,and the customer <br /> approved tank drawing to ensure all parts are present and cut to length As soon as all parts have <br /> 14 <br />