My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0007814
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
632
>
3500 - Local Oversight Program
>
PR0505525
>
ARCHIVED REPORTS XR0007814
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2019 5:54:12 PM
Creation date
7/15/2019 4:31:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007814
RECORD_ID
PR0505525
PE
2953
FACILITY_ID
FA0002387
FACILITY_NAME
KEYSTONE AUTOMOTIVE INDUSTRIES INC
STREET_NUMBER
632
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14907033
CURRENT_STATUS
02
SITE_LOCATION
632 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> I� <br /> i Procedures 1 1 1 1 <br /> I <br /> i - <br /> Single-Phase 2-Wire Wiring Diagram Three-Phase Wiring Diagram Pump Won't Start <br /> for Submersible Motors for Submersible Motors I POSSIBLE CAUSE CHECK THIS BY CORRECT THIS BY <br /> 10 2-Wire Pump Quick Disconnect I No power at the motor Check for voltage at the control box or It there is r o voltage at the contro}pane[ <br /> with Ground 1 1 power Supply panel check the leader panel for tripped circuits <br /> and reset those circuits <br /> Fused j Fuses are blown or the Turn off the power and remove the fuses Replace the blown fuses or reset the circuit <br /> ' Pressure Disconnec circuit breakers have Check for continuity with an ohmmeter breaker It the new fuses b}ow or the circuit <br /> Switch Switch j tripped breaker tops the electrical Installation <br /> Switch <br /> Pressure motor and woes must be check for defects <br /> Black (3 phase motors artly) Check for Voltago on the line and load side Replace any burned heaters or reset <br /> MMotor starter overloads of the starter Check the amp draw and inspect the starter for other damage If the <br /> Black are burned or have tripped make sure the heater Is sized correcly heater trips agars+ check the supply voltage <br /> Ensure <br /> that heaters are sized correct[y <br /> Green j he trip selling Is appropriately adjustedand <br /> Magnetic (3 phase motors only) Energize the conal circult and check for I!there Re no voltage check the control dram <br /> Starter I tarter does not energize voltage at the holding coil Hisao Ithere isvolrage checlkthe hodingcog for <br /> Pump$ <br /> weak connections.Ensure that the hoktng cad is <br /> Motor <br /> designed rn operate with the a 21aWe control <br /> Teen Well WOOD Replace the cal 6defects are found <br /> """" Seal Detective controls Chad( and <br /> yh�,�M� M �q g Inspect m four Replace worn or defective parts or controls <br /> ,+s1�rn,A r control <br /> '" �r 'a � ` I Motor or cable Is defective Tum off the povvas and dlsconnac the molar if an open or grounded winding is found <br /> Figure 4 F1 Gre$ leads Imm the con, bnuk Measure the lead remove the motor from the well and recheck <br /> g todead resistance with an ohmmeter(set to R the measurements with the lead separated <br /> I x 1) Measure the lead-to-ground values with from the motor Repair or replace the motor <br /> an ohmmeter(set to R x 1 OOK) or cable <br /> (i phase motors only) Turn off the power and discharge the when the meter is connected to the <br /> Defective capacitor capadtor bbyv shorting the leads together capacitor the needle should jump toward ll <br /> Single-phase 3-Wife Control Box } Check n w[fh an analog ohmmeter(set to ((zero}}ohms end slowly drift back to lnfrn[ty <br /> for Submersible Motors R x i lHlk) Ir) fieplace capacflar c1 it is defecttve <br /> Defective pressure switch Watch the pressure gauges as the Replace as necessary <br /> 230v { or the tubing to It Is pressure switch operates Remove the <br /> Pressure switch plugged tubing and blow through It <br /> 115v <br /> The pump Is mechanically Tum off the power and manually rotate the If the pump shaft doesn t rotate remove the <br /> - Lr Fused I bound or stuck pump shaft.Also check the motor shaft rota um and examine it If necessar <br /> Disconnect <br /> t I ton the shaft height,and the mature amp dismantle it and check the impellers and seal <br /> it draw to see d it Indicates a Pocked rota) for obstruction Check for motor corrosion <br /> Control A . a Pump Does Not Produce Enough flow(GPM) <br /> Boa t.5 O O O k2 <br /> ac IPOSSIBLE CAUSE CHECK THIS BY CORRECT THIS BY <br /> o reed w We Golfed line for 115V operation I (3-phase motors only) Check to make sure the electrical Correct the wiring For single phase motors <br /> Shaft Is turning in the connections In the control panel are check the wiring diagram on the motor For <br /> ed i wrong direction correct three phase motors simply switch any two <br /> power leads <br /> Well I Pump Is oparaling at the Check for low voltage and phase Replace defective parts or contact power <br /> Sul wrong speed(too slow) Imbalance company as applccabie <br /> 2 � n k� � f' Check valve is stuck(or Remove the check vaive Re install or replace <br /> r <br /> rr F installed backwards) <br /> Parts or fittings In the Install a pressure gauge near the Convert the PSI <br /> g you read on the gauge to Feet <br /> Figure 6 I pump are worn discharge port staff the pump and of Head by <br /> —or— grade illy close the discharge valve Read PSI x 231 WPSI= ft <br /> Impellers or Inlet Strainer lthha pressure at shutoff (Do not allow the <br /> Is clogged pump to operate for an extended period at Specific Gravity <br /> shutoff) Add to this number the number of feet <br /> 4. Starting the Pump for the First Time I (vertically)from Vie gauge down to the waters <br /> Pumping level <br /> A Attach a temporary horizontal length of pipe to the riser pipe Refer to the pump curve for the model you are <br /> working with to determine the shutoff head you <br /> 8 Install a gate valve and another short length of pipe to the temporary pipe I should expect for that mode€ if that head is <br /> C Adjust the gate valve one-third of the wayo dose to file figure you came up with(above) <br /> open the pump is probably DK If not remove the <br /> D Verify that the electrical connections are In accordance with the winng diagram I pump and inspect Impellers chambers etc <br /> The water level In the well Check the drawdown In the well while the if She pumping water level(inchiding drawdown) <br /> After proper rotation has been checked start the pump and let It operate until the water may be too low to supply pump is operating I runs clear of sand silt and other impurities w not AT LEAST 9 FEET above the pump s <br /> flow desired inlet strainer either <br /> P Slowly open the valve In small inc4lments as the water clears until the valve is all the -or— t Lower the pump further down the wail <br /> Collapsed well 2 Throttle flack the discharge valve to decrease <br /> way open The pump should not be stopped until the water runs clear the.low thereby reudingdrawdown <br /> G If the water is clean and clear when the pump Is first started,the valve should still be Broken shalt or coupling Pull pump and inspect Replace as necessary <br /> opened until it is a4 the way open There are leeks In the PW the pump out of the well 7hp suction pipe valves and fittings must be <br /> fittings or piping made tight Repair any leaks and relighien <br /> all loose[lain s <br /> Page 5 le` <br /> Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.