Laserfiche WebLink
SErrIC SYSTEM CONSTRUcriols <br /> All septic system requirements must be in accordance with the San Joaquin County Environmental Health Sewage Standards. <br /> For gravity systems,the house pad must be raised to permit gravity flow through both septic tanks and into leach field <br /> The double septic system design shown on this plan must comply with the following:(Sec. 10 Sewage Standards.) SEEPAGEE PITS <br /> MA (P <br /> ITS tTYP) <br /> Minimum distance from well to seepage pits 150' <br /> Mimmtundistance from trenches to well too, <br /> Minimum distance from foundations,driveways and pools 10' <br /> Maximum length of individual leach line too' <br /> Maximum width of trench 24" <br /> Maximum grade of line 3"per 100' <br /> Preferable grade of line T'per 100' <br /> Distance between lines 10'edge to edge <br /> Minimum depth of rock below approved perforated pipe 12" <br /> Minimum depth of rock over approved perforated pipe 2" <br /> Maximum depth of trench 42" LEACHLINES AND TRENCHES <br /> Mimmum distance between leach line and septic tank 5' (TYP.-MIN.10'EDGE TO EDGE) <br /> Maximum soil cover over leach line 24" <br /> Minimum soil cover over leach line 6" <br /> During leachfield construction,the sidewalls and floors of the leachline trenches must be scarified to open smeared soil surfaces possibly <br /> caused from the backhoe excavations.Seepage pits are normally scarified by a"cleat"on the outside of the auger flight.All excavations <br /> should be inspected by a representative from San Joaquin County Public Health Services Department Environmental Health Division, <br /> before placement of drain rock. Telephone at least 48-hours in advance of inspection (209) 468-3284 <br /> Leachfield areas cannot be driven or parked over,and no swclures tart be built over these areas.Final grading of the leachfields must <br /> be such that drainage water from domestic irrigation or rainfall cannot collect and pond over the leachfields.Only grasses and small <br /> shrubs may he planted over the fields,with trees and large shrubs planted at least 15 feet away. The designated replacement area must <br /> remain as such,with no permanent structures built in this area. <br /> SEPTIC SYSTEM NIAINTENANCE <br /> The septic system installed for the respective residence must consist of a dual leachfield system in accordance with San Joaquin Sewage <br /> Standards,Section 10.1.For the system to have maximum theoretical longevity,the leachfields must be manually switched between DISTRIBUTION <br /> each other on an annual basis.This can be accomplished with a push-pull"gate"valve,which will be on each of the two effluent lines BOX(TYp) o <br /> exiting the secondary septic tank. It may be a requirement by the Environmental Health Department that the valves be located within SECONDARY SEPTIC TANK o o phIxlpR <br /> / o (SEE ATTACHED NOTES) (OR) o o TANK <br /> the second compartment of the secondary tank. This second compartment must also have an installed filter. BULL RUN VALVE ' <br /> The Environmental Health Department will require that the tanks be pumped every three years.Therefore,access to the tanks by pumper (IN CHRISTIE BOX) <br /> trucks must be maintained Since the septic systems will be installed in fine-grained clay soils,sadiron from a water softener may hasten <br /> 0 <br /> the clogging mechanisms of this soil type,which may lead to septic system failure. Therefore,water softeners should be avoided or C PRIMARY SEPTIC TANK <br /> limited in use. Water from domestic irrigation or rainfall must not be allowed to congregate in the leachfield areas. <br /> By signing below,the homeowner has read and understands the construction and maintenance procedures,as stated above and agrees <br /> to perform these recommended procedures.This information must be transferred to a buyer upon sale of rile applicable residences. <br /> `PpFESS(p4,a <br /> W tE1tfl f <br /> SIGNED PRINTED NAME DATE WQ yF�hyo '''r <br /> DOUBLE SYSTEM LEACHFIELD REQUIREMENTS` <br /> -03 <br /> IN ACCORDANCE WITH SAN JOAQUIN COUNTY SEWAGE STANDARDS C FTP t <br /> .�fa'cwatc� �P <br /> Leachhne Length(ft) Size of Primary and No.and Dia.(in.) ?\op clilo � PLAN VIEW <br /> No of Bedrooms Requirements Secondary Septic Tanks of Seepage Pits No.and Length(h.)of Leachimes — - <br /> 3 300 n 1200+1200 gals 2-42'(160 R eq.) 2-70 ft 160'+140'=300') TYPICAL DOUBLE SEPTIC SYSTEM DESIGN <br /> 4 400 ft 1600.1600 gals 342'(240 R.eq.) 3-55 ft(240'+165'=405') <br /> 5 500 ft2000+2000 gals 3-42•(240 ft eq.) 3-85ft(z40'-255'=495) R9 K L E I N F E L D E R HEATHER MOOR ESTATES <br /> UNIT No.2 <br /> 6 600 h 2000+2000 gals 4-42"(320 ft eq) 4-70 ft(320'+280'=600') <br /> (Except for septic tank sizes.all requirements above pertain to a single leachfield and therefore must be doubledj. <br /> DA'E PRODUCESED SAN JOACUIN COUNTY,CALIFORNIA <br /> D.10,'iti2001 DATE RevI <br /> PROD NO 20-7921-02 FILENAME-2011D620.FH9 <br />