COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3242
>
1600 - Food Program
>
PR0526196
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 11:29:38 AM
Creation date
7/18/2019 2:52:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526196
PE
1624
FACILITY_ID
FA0017727
FACILITY_NAME
THE CAJUN SPOT
STREET_NUMBER
3242
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
23860002
CURRENT_STATUS
01
SITE_LOCATION
3242 W GRANT LINE RD
P_LOCATION
01
P_DISTRICT
005
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
will be a cleanable, light colored material (either painted sheetrock or a drop- <br /> ceiling with Vinyl Rock panels). <br /> 3. All ice machines and bins, food preparation sinks, dishwashing sinks (dish- <br /> washing units), display cases and refrigeration units, and any other food service <br /> equipment which discharges liquid waste, shall be plumbed therein with an <br /> indirect connection through an air gap (height of air gap must equal two times the <br /> inside diameter of the discharge tube. H=2xl.D.) into a floor sink or other <br /> approved waste receptor. All floor sinks are to be positioned to be readily <br /> cleanable, accessible for inspections, and must be flush with finished floor. Do <br /> not place floor sinks inside walk in refrigeration units or cabinets. [CURFFL <br /> §114100 and §114150] <br /> 4. Adequate and suitable storage space must be provided for dry and cold storage. <br /> The following recommended methods may be used: a) A floor area equivalent <br /> to 25 percent of all kitchen space; b) Sufficient approved shelving of ninety-six <br /> (96) linear feet of shelving that is eighteen (18) inch deep, or c) 144 square feet <br /> of actual dry shelving area. <br /> 5. The walk-in refrigeration unit shall be flashed or sealed to adjacent walls and/or <br /> ceiling to exclude vermin. The unit shall also be designed to be closed and <br /> sealed to the floor or be constructed integral with the floor. When opened food <br /> containers are stored inside this unit, the flooring shall be continuous/contiguous, <br /> coved at the floor wall interface to a height of four (4) inches and a minimum <br /> radius of three-eighths (3/8) of an inch provided. [CURFFL §114040 and <br /> §114150] <br /> 6. The approved flooring that was discussed with the Joe Koslowski, the flooring <br /> contractor, and Roger Page on January 6, 2006 was General Polymers "TPM <br /> #115 Upgraded Troweled Mortar (U3/U4)" installed throughout. Under the <br /> cooking equipment in the hallway and at least 5 feet around the equipment you <br /> must include in the mixture the General Polymers "FasTop S Urethane Slurry <br /> System" in order to meet the minimum temperature resistance. Both floors must <br /> be applied at 3/16-inch minimum thickness throughout. Under the cooking <br /> equipment and at the floor-wall iunctions you must apply the slurry as smooth as <br /> possible for cleaning purposes. <br /> The EHD must be kept informed of the construction progress. A final inspection must <br /> be performed, operating permit fees paid, and approval to operate granted prior to <br /> opening for business. All equipment must be installed and thorough cleaning <br /> completed prior to the final inspection. Inspections must be scheduled at least 48 hours <br /> in advance. Charges for additional inspections, re-inspections and/or consultations <br /> may be assessed at the EHD hourly rate of $ 93.00 per hour. <br /> Any item(s) inadvertently overlooked in the plan check process, which is not in <br /> compliance with applicable State laws, and/or city or county ordinance codes, shall be <br /> Plan Check Approval -2- December 23, 2005 <br />