Laserfiche WebLink
REMOX 06/08/92 <br /> . 04/17/92 <br /> Check the influent and effluent from the system and the vapor <br /> from the wells using a Photovac lOS50 chromatograph. System <br /> set at 64 . 6% air dilute. <br /> 04/21/92 <br /> Check the influent and effluent from the system and the vapor <br /> from the wells using a Photovac 10550 chromatograph. System <br /> set at 63 . 4% air dilute. <br /> 04/24/92 <br /> Check the influent and effluent from the system and the vapor <br /> from the wells using a Photovac lOS50 chromatograph. System <br /> set at 54 . 9% air dilute. <br /> 04/29/92 <br /> Check the influent and effluent from the system and the vapor <br /> from the wells using a Photovac 10550 chromatograph. System <br /> set at 58 . 2% air dilute. <br /> 05/15/92 <br /> • Check the influent and effluent from the system and the vapor <br /> from the wells using a Photovac IOS50 chromatograph. System <br /> set at 64% air dilute. <br /> 05/21/92 <br /> Collect samples from the influent and effluent of the system <br /> for WEGE laboratory. System set at 74% air dilute. <br /> 06/02/92 <br /> Collect samples from the influent and effluent of the system <br /> for WEGE laboratory. System set at 70% air dilute. <br /> The VOC emissions have never exceeded the 52 lb/day emission limit <br /> for the site. No evidence of Dichloroethylene (DCE) , <br /> Trichloroethylene(TCE ) or Tetrachloroethylene (PCE) were found <br /> during examination of the chomatograms of the samples taken to the <br /> WEGE laboratory. <br /> 2 <br />