My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0008125
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1448
>
3500 - Local Oversight Program
>
PR0544673
>
ARCHIVED REPORTS XR0008125
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2020 6:26:41 AM
Creation date
7/18/2019 3:24:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008125
RECORD_ID
PR0544673
PE
3528
FACILITY_ID
FA0006182
FACILITY_NAME
REGAL STATION #604
STREET_NUMBER
1448
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
02
SITE_LOCATION
1448 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REMOX 06/08/92 <br /> . ON SITE ANALYSIS <br /> In addition to the bag samples collected for the WEGE laboratory <br /> samples may be run on site using a Photovac 10550 PID <br /> chromatograph. <br /> The influent and effluent samples are collected from the same <br /> ports as the bag samples but 60 cc syringes are used to collect <br /> the sample and 0 . 5 cc of the vapor sample are then infected <br /> directly into the PID chromatograph. The resulting chromatogram <br /> is then compared to a standard calibration run on the same <br /> chromatograph prior to the sample run. <br /> During the initial month of operation, three effluent samples were <br /> obtained during the day and analyzed using the 10550 <br /> chromatograph. The highest value is used to calculate the VOC <br /> poundage per day produced. Presently, an influent and an effluent <br /> sample are obtained upon arrival to the site. Adjustments are <br /> then made to the vapor extraction system: removal of liquids from <br /> the condensation traps; closing the air dilute valve to maximize <br /> vapor removal, without causing the REMOX Unit to shut down due to <br /> high temperature shut off (greater than 15500F) ; and closing the <br /> pump bypass to create maximum flow and vacuum from the wells. <br /> Once, these adjustments have been completed and the system has <br /> stabilized, influent and effluent samples are again obtained, <br /> along with samples from the individual extraction orifices <br /> (wells) . The site is then secured until the next visit. <br /> FLOW RATES <br /> Flow rates are measured at the site by use of orifice plates. <br /> A one inch orifice is placed in line for each well and a three <br /> inch orifice is used to measure the total flow. <br /> An orifice plate restricts the flow of air across it. This <br /> restriction causes a pressure drop across the orifice. By <br /> measuring the resulting pressure change across the orifice it is <br /> possible to calculate the air flow rate. <br /> The flow rate is calculated by the pressure drop (millimeters (mm) <br /> water) across a square edge orifice plate. <br /> Ve = CK sgr(P) Q = AVe <br /> Where: <br /> Ve= velocity in feet per minute ( fpm) <br /> C = Orifice Coefficient = 0. 65 (for orifice used) <br /> K = Constant = 794. 6 mm water <br /> P = Pressure differential across the orifice <br /> Q = Flow rate in cubic feet per minute (CFM) <br /> A = Area orifice in square feet. 11' = 0 . 00545 ft2 <br /> 3" = 0 . 04909 ft2 <br /> Q = A X 0 . 65 X 794. 6 X sgr(P) <br /> 4 <br />