My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0008160
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1448
>
3500 - Local Oversight Program
>
PR0544673
>
ARCHIVED REPORTS XR0008160
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 3:44:24 AM
Creation date
7/18/2019 3:28:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008160
RECORD_ID
PR0544673
PE
3528
FACILITY_ID
FA0006182
FACILITY_NAME
REGAL STATION #604
STREET_NUMBER
1448
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
02
SITE_LOCATION
1448 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
246
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VAPOR SAMPLIW <br /> On site sample analysis is performed using a Photovac lOS50 PID <br /> chromatograph. <br /> The vapor samples are obtained by attaching a dedicated air tight <br /> 60 cc syringe to a sample port on the vapor recovery manifold, <br /> well side of the orifice plate, with air tight fitted polytubing. <br /> The sample port is then opened and the syringe is purged by <br /> pulling and pushing the syringe plunger several tames filling and <br /> depleting the syringe of that particular wells vapor stream. Then <br /> the syringe is filled, the sample valve closed and forceps are <br /> clamped onto the soft polytubing to create an air tight seal for <br /> the syringe before removing the syringe from the sample port. <br /> Once the 60 cc syringe is removed with the forceps clamped <br /> polytubing attached, the plunger is pushed into the syringe to <br /> create pressure within the syringe and released to allow the <br /> vapors that have been captured to reach equilibrium. A small <br /> dedicated needle attached to a dedicated I cc suringe is then <br /> inserted into the 60 cc syringe via the soft tubing for obtaining <br /> the sample to be injected into the PID-GC. Again the Zcc syringe <br /> is purged numerous times prior to filling it with the sample. All <br /> but 0 .5 cc of the sample is ejected into the air prior to <br /> inDecting the remaining 0.5 cc syringe sample into the GC-PID (the <br /> calibrant injection is 0.5 cc) . Once the chromatogram has been <br /> E recorded an instrument blank is run prior to the next sample. The <br /> instrument blank will indicate if residual peaks are being carried <br /> onto the next analysis. The resulting chromatogram is then <br /> E compared to a standard calibration run on the same chromatograph <br /> prior to the sample run. <br /> While the GC-PID analysis is running for a particular sample (15 <br /> minutes per sample run) , vacuum influent readings are obtained <br /> 1 from the wells by attaching a manometer calibrated in ma water to <br /> sample ports at the well heads. These readings show the mm water <br /> pressure or vacuum that is being created at each well. <br /> COLLECTING LABORATORY SAMPLES <br /> INFLUENT SAMPLE <br /> The influent sample is obtained from a sample port located after <br /> the system vacuum pump before the carbon canisters. Sterile poly <br /> tubing is then used to attach a 1 liter tedlar bag, fitted with a <br /> special septum "valve" and tubing bib, to the sample port. The <br /> sample port is on the pressure side of the pump and therefore the <br /> bag will fill without need of a pump. Once the tedlar bag is <br /> filled, its' valve is closed and locked; the appropriate label is <br /> placed on the tedlar bag. <br /> • <br /> R604 vapor, 7%31/92, p. 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.