Laserfiche WebLink
PLENUM PROTECTION INCLUDES- FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS <br /> NOZZLE BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE <br /> VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE <br /> VISIT FOR ONE TESTI ADDITIONAL VISITS WILL RESULT IN ADDITIONAL <br /> DUCT PROTECTION CHARGES), ONE MECHANICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF <br /> NOZZLE 2', PERMIT, AND SYSTEM TEST. <br /> EXCLUDES. UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE <br /> DETECTORS ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND <br /> CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD <br /> EXTINGUISHER(S), ON—SITE RE—PIPING DUE TO EQUIPMENT LAYOUT CHANGES. <br /> DETECTION LIQ <br /> I <br /> r I <br /> I i NOTES <br /> i - FIELD PIPE DROPS AS SHOWN <br /> / APPLIANCE PROTECTION SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS <br /> NOZZLE - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, <br /> AGENT LINE - SALAMANDERS, ETC. <br /> MAXIMUM 9 ELBOWS IN SUPPLY LINE. <br /> - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. <br /> - IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE, <br /> - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. <br /> - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE <br /> SIZE, NOT THE OVERALL APPLIANCE SIZE, <br /> - THIS FIRE SYSTEM COMPLIES WITH U,L, 300 REQUIREMENTS <br /> SPECIFICATIONS <br /> TYPICAL ANSUL 1102 SYSTEM LAYOUT THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE—ENGINEERED <br /> REMOTE WITH REMOTE MOUNTED AUTOMAN TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED <br /> SYSTEM CONTROL AUTOMAN MANUAL WITH UNDERWRITERS LABORATORIES, INC. (UL) <br /> WITH AGENT TANK ENCLOSED PULL STATION <br /> THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION <br /> WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE <br /> FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT—OFF APPLICATIONS. <br /> THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM <br /> ACETATE—BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT <br /> OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS <br /> WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. <br /> THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE <br /> LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND <br /> INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING <br /> SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ <br /> LINKAGE ASSEMBLY. <br /> Job #1 3801292 <br /> Job Nave] Snack Bar - Lathrop, CA <br /> System Size ANSUL-3.0/1,5 Total FP required, 13 <br /> Hood # 1 8' 9,00' Long x 54' Wide x 24' High <br /> Riser # 1 Size, 12' x 14' <br /> ✓OBSnack Bar - Lathrop, CA <br /> s -� a LOCATION LATHROP, CA, 95330 <br /> 0 IN /� DATE 4/23/2019 ✓Og 3801292 <br /> '•Inter k •' -�--- IJ1YC , 6 DR91YN gYTT-91 <br /> REV SCALE 3/8' = 1'-0' <br />