My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012627
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TAM O SHANTER
>
6215
>
3500 - Local Oversight Program
>
PR0544683
>
ARCHIVED REPORTS XR0012627
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2019 3:17:56 PM
Creation date
7/22/2019 8:18:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012627
RECORD_ID
PR0544683
PE
3528
FACILITY_ID
FA0004953
FACILITY_NAME
NORMAC INC
STREET_NUMBER
6215
STREET_NAME
TAM O SHANTER
STREET_TYPE
DR
City
STOCKTON
Zip
95209
APN
09405011
CURRENT_STATUS
02
SITE_LOCATION
6215 TAM O SHANTER DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 12, 1969 - UST removed aluiig r:1th about 25 CY spoil. Strong <br /> gasoline odor noted, and discolored soil observed at west end of <br /> tank near pump island. Three (3) soil samples taken; one at Each <br /> end of the tank and one about 2' below the tank:. Samples delivered <br /> to Canonic labs under Chain-of--Custody. Spoil was returned to hole. <br /> July 319 1969 - Sample analysis completed; see Table i for results. <br /> January 19-23, 1990 - Site re--entered, existing spoil removed, and <br /> an estimated 300 CY of additional spoil was removed, which resulted <br /> in a pit approximately 30' long X 19' wide X 21 ' deep. A total of <br /> seven (7) samples were collected, (see Plates IX Es X,) and were <br /> transported under Chain-of--Custody to FOL Environmental Laboratory <br /> for analysis. The spoil was placed on plastic on an asphalt storage <br /> area, and covered with plastic. <br /> February 12, 19905 - FOL Environmental issued laboratory analysis of <br /> the above samples; refer to Table II for test results. <br /> The results of the lab tests showed that the two bottom samples <br /> showed very minor amounts of BTX&E, and no detectable levels of <br /> TPH-G, EDB, or organic lead. The sidewall samples on the northeast, <br /> east, and southeast portions of the pit were clean. The two <br /> sidewall samples on the northwest and southwest end of the <br /> excavation revealed low levels of Toluene, Xylene, and Ethyl <br /> Dibromide. Only the sample on the southwest side of the pit, <br /> (SW-2W,) showed detectable levels of TPH--6. <br /> June 20, 1990 -- Correspondence from EHD requiring a work plan for <br /> borings and/or groundwater monitoring wells. <br /> In order to define the extent and configuration of the plume, we are <br /> submitting the following Workplan for ,your review. Work will <br /> commence as soon as approval is received from your office. <br /> PROPOSED WORKPLAN: <br /> 1, Drill five (5) 4" auger holes to a maximum depth of 40' at the <br /> approximate locations shown an the attached Exhibit A. If it is <br /> logistically feasible, boring No. 8-•2 will be started -From the <br /> bottom of the existing excavation. If that is not possible, it will <br /> be located as close to the side of the pit as possible. <br /> 2. Split--spoon sail samples will be taken at 1 ' & 5' , and every 5' <br /> to and including the bottom of the each boring. The lithology will <br /> be described, and samples taken and/or supervised by a Registered <br /> Geologist. Upon completion of this pha,e of the work, all borings <br /> 2 <br />