Laserfiche WebLink
DATE May 16, 2006 <br /> 7-ELEVEN, INC. QUARTERLY REPORT <br /> . Store Number 7-Eleven Store#19976 <br /> Site Address 1399 North Main Street, Manteca, CA <br /> 7-Eleven Contact Mr Ken Hilliard <br /> Consulting Company SECOR International, Inc —Mr Jaff Auchterlonie <br /> SECOR Project No 77EL 19976 06 <br /> Primary Agency San Joaquin County Environmental Health Department <br /> (SJCEHD) - <br /> WORK PERFORMED THIS QUARTER [First—20061 <br /> 1 Conducted groundwater monitoring and sampling on January 18, 2006 <br /> 2 Performed periodic oxygen infection in wells SP-1 and SP-1A <br /> 3 Prepared quarterly groundwater sampling and remediation progress report <br /> WORK PROPOSED FOR NEXT QUARTER [Second— 2006] <br /> 1 Perform quarterly groundwater sampling and prepare status report <br /> 2 Continue periodic oxygen infection into wells SP-1 and SP-1A <br /> 3 Install three additional oxygen infection wells and one additional monitoring well per <br /> approval of work plan from SJCEHD and submit report <br /> 4 Submit report of evaluation of oxidation capacity of groundwater to CRWQCB <br /> DISCUSSION <br /> An active 7-Eleven convenience store and gasoline station is operated at the site (Figures 1 <br /> and 2) Monitoring and sampling has been conducted at the site since the third quarter of <br /> 1998 The current groundwater monitoring and sampling data are summarized in Table 1, <br /> and presented in Figures 2 and 3 Historical groundwater monitoring and sampling results <br /> are summarized in Table 2 The well completion details are summarized in Table 3 <br /> Current Site Information <br /> Current Phase of Project Groundwater Monitoring and Periodic <br /> Remediation <br /> Frequency of Monitoring and Sampling Quarterly, Nine wells- MW-1, MW-1 A, <br /> MW-2, MW-3, MW-4A, MW-5, MW- <br /> 5A, MW-6, and MW-7 Semi-annual, <br /> One well —MW-4 <br /> Are Liquid Phase Hydrocarbons Present On-site No <br /> Water Supply Wells within a 2,000-foot radius and 68 wells within 2,000 feet in various <br /> their Respective Direction directions (Survey of Sensitive <br /> Receptors, April 12, 1999, IT) <br /> Current Remediation Techniques Oxygen infection and soil vapor <br /> extraction <br /> Permits for Discharge San Joaquin Valley Air Pollution <br /> Control District Permit to Operate No <br /> N-5013-1-0 <br /> • Historic Range in Depth to Water, Q3-98 to Q1-06 MW-1, 14 17 to 25 51 feet bgs <br /> 19976 06-1Q Report doc SECOR International Incorporated <br />