Laserfiche WebLink
OB NAME 7-Eleven Store#19976 JOB NUMBER 77EL 19976 03 1006 <br /> SITE ADDRESS 1399 North Main Street START DATE 5/12/2003 <br /> Manteca, CA DATE PREPARED 5/9/2003 <br /> REPAIRED FOR Randy A PREPARED BY Casey Sanders <br /> _WORK REQUEST FORM <br /> SCOPE OE WORK 021NJECTION OPERAT1014&MAINTENANCE I , w ' <br /> 1) Arrive at site-_Review(1} HASP, (2)work order,then call Casey_Sanders in Sacramento <br /> Check in with 7-Eleven store manager Store Phone (209) 239-3252_ Franchisee Manjit and Gurpal Grewal <br /> 2) DTW should be approximately 20' bgs <br /> 3 PRIOR TO OXYGEN INJECTION INTO ANY WELL, collect DO reading from ail monitoring wells, <br /> Wells to receive injection SP-1 and SP-1A simultaneously _ <br /> 4 At each well, connect tubing from the oxygen canister to the injection well The tubing must reach the bottom of <br /> the well, and the well sealed around the tubing <br /> Connect tubing at bottom of well to air diffusers <br /> 5 Install 2"slip caps on monitoring wells near the wells receiving injection MW caps should be plumbed to <br /> allow LEL measurement at the ca take measurement without removing the slip cap) <br /> 6 <br /> Open oxygen canister regulator to release approx 150 cubic feet ofoxygen into each injection well <br /> Rate of injection can vary between 30-50 cfh <br /> 7) During infection, measure Oz levels with an LEU02 meter in area surrounding the well head and at oxygen cylinders <br /> Oxygen levels should be below 23 5% See HASP for details <br /> Also measure 02 levels in any monitoring well near the well(s) inject <br /> ian <br /> 8) Upon completion of injection, collect DO readings from all wells listed above <br /> 9 Call Casey Sanders or Jaff Auchterlonie in Sacramento before you leave the site <br /> 10) Fill Out Equipment Billing Sheet for all equipment used on the job and attach with field notes <br /> 11) Give copies of all notes and COC's to Brian Carey,ASAP <br /> 12) Bill labor time to 77EL 19976 03 1006 (max 8 hours onsite labor) _ <br /> Bill travel time to 77EL 19976 03 1015 <br /> 13) Please check Power situation There should be a service located at the site Document Amps of service, <br /> Is it single phase or 3 phase power, etc Check if the meter has an electrical plug connected to it <br /> Site Health&Safety Plan <br /> D 0 Meter, LEU02 meter – — <br /> _02 canisters, hosing, diffusers, regulators, speed bumps, NO SMOKING SIGNS <br /> 112", 9116',and 15116" sockets, and other misc tools <br /> Traffic control pylons, cones,etc K <br /> 37E � t# Q -III, <br /> "'lilt""-& <br /> Direct all questions to Jaff Auchterlonie, (916)861-0400 ext 223-office <br /> PROJECT MANAGER, Jaff Auchterlonie AUTHORIZATION <br />