Laserfiche WebLink
Health and Safety Plan t 1 <br /> The Southland Cor -Store located at 1399 N Main St, Manteca, CA September 19, 1996 <br /> Table 4 Air Monitoring Summary <br /> ,lob Task Level PPE T InstrumentT Frequency <br /> Dnlfing/Bonng/Sod Level D or PID' or FID2, Start up of work,then 30 minutes <br /> Sampling Modified Level D O,/LEL ' or to continuously <br /> DT` <br /> Well Installation Level D or PID or FID, Start up of work at each new task <br /> Modified Level D 021LEL, or location <br /> DT <br /> Well Monitoring and Level D or PID or FID, Start up of work at each new task <br /> Maintenance Modified Level D 021LEL, or location <br /> DT <br /> Soil Gas Survey Level D or PID or FID, Start up of work at each new task <br /> Modified Level D 02/LEL,or location <br /> DT <br />' Aquifer Pump Test Level D or PID or FID, Start up of work at each new task <br /> Modified Level D 02/LEL, or location <br /> DT <br /> Tank Removal Level D or PID or FID, Start up of work at each new task <br /> Modified Level D 02/LEL, or location <br /> DT <br /> Excavation/Trenching Level D or PID or FID, Start up of work at each new task <br />' Modified Level D 021LEL,or location <br /> DT <br /> Groundwater Sampling Level D or PID or FID, Start up of work at each new task <br />' Modified Level D 02/LEL, or location <br /> DT <br /> PID, Photoionizabon Detector <br /> 2 FID, Flame Ionization Detector <br /> 3 021LEL, Oxygen Level and Combustible Gas Meter <br /> DT, Benzene Detector Tube <br /> Note "Start up of work at each new task location" means to monitor the air quality at each new <br />' operation on the site The breathing zone is the area inside a 1-foot radius around the head <br /> r <br /> FLUOR DANIEL GTI 97 <br /> r.J� <br />