Laserfiche WebLink
I SEP 02 '92 12 15 GOLDEN P.4/5 <br /> DAY OR NIGHT R TC T $ • NO. <br /> 'TELEPHONE <br /> (510) 236-1393CERTIFIED SERVICES COMPANY ct�g N <br /> I 255 Parr Boulevard + Richmond, Galifvrnis 94901 JOB NO <br /> c..-tc.hscn, Iris. 889 1 <br /> ppp TANK NO <br /> <imr� i�: G6/11/92 '61:49 :46 <br /> ILOCATION DATE TIME <br /> U:j 5 sAal Gds t_ea}1!1.i14 SMPh 4+6 <br /> TEST METHOD LAST PRODUCT <br /> This is to certify that i have personally determined that this tank is in accordance with the A.menican <br /> Petroleum Institute and have found the condition to be in'accordance with Its assigned designation <br /> This certificate is based on conditions existing at the time the Inspection herein set faith 'was <br /> completed and is Issued subject to compliance with all qualifications and instructions <br /> 000 Gdl2un Tdiik ::kFE FOR FIRE <br /> TANK SIZE CONDITION <br /> 61177271 -707-9 96 <br /> REMARKS LOWER EAFLUSIVE LIESS171A, <br /> u _ INC .. _ l.,_ _ _ .0 —- <br /> •,i, OF . ' .,,. . FORT; DESTROYER kT OCR PERMITTzD ;fAZARDO(L;CUT — <br /> in the event of any physical or atmospheric changes affecting the gas-free conditions of the above tanks, or If in any doubt, <br />' Immediately stop all hot work and contact the undersigned This permit is valid for 24 hours if no physical or atmospheric <br /> changes occur <br /> STANDARD SAFETY DESIGNATION <br />' SAFE FOR MEN Means that in the compartment or space so designated ia) The oxygen content of the atmosphere is at least <br /> 19.5 percent by volume, and that (b) Toxic materials in the atmosphere are within permissable concentrations, and (c) In the <br /> judgment of the Inspector, the residues are not capable of producing toxic materials under existing atmospheric conditions <br />' while maintained as directed on the Inspector's certificate <br /> SAFE FOR FIRE Means that in the compartment so designated (a) The concentration of flammable materials in the <br /> atmosphere is below 10 percent of the lower explosive limit, and that (b) In the judgment of the Inspector, the residues are <br /> not capable of producing a higher concentration that permitted under existing atmospheric conditions in the presence of fire <br />' and while maintained as directed on tree Inspector's certificate, and further, (e) All adjacent spaces have either been cleaned <br /> sufficiently to prevent the spread of fire, are satisfactorily Inerted, or in then cases of fuel tanks, have been treated as deemed <br /> necessary b�he inspector <br /> The and signed Itive acknowledges receipt of this certificate• and understands the conditions and limitations under <br /> which i 8sissue � <br />' fRMPR 7 7iVE TITLE IN9P TOA <br /> CP506s <br /> 1 <br />