Laserfiche WebLink
*E1 <br /> CONSTRUCTION DETAILS FOR GROUND WATER MONITORING AND VAPOR EXTRACTION WELLS 1991-1993 <br /> Exxon Seance Station No 7-0137 <br /> 1605 S El Dorado Street <br /> Stockton,California <br /> Elevation Depth to Ground Water Borehole Casing Screened Filter Pack <br /> Well TOC Casing Water Elevation Diameter Diameter Interval Slot Size Interval Filter Pack <br /> No (ft msl) Material (ft) (ft mil) (inches) (inches) (ft) (inches) (ft) Material <br /> MW1 1186 PVC 565 55 12 4 35-55 NR 33-565 2112 Sand <br /> MW2 1254 PVC 565 55 12 4 35-55 NR 33-565 2/12 Sand <br /> MW3 1211 PVC 565 55 12 4 35-55 NR 33-565 2112 Sand <br /> MW4 1337 PVC 615 60 10 4 40-60 NR' 38-615 NR' <br /> MW5 1184 PVC 615 60 10 4 40-60 NR' 38-615 NR' <br /> MW6 1080 PVC 565 55 10 4 35-55 NR' 33-565 NR' <br /> MW7 1136 PVC 61 60 10 4 40-60 NR' 38-61 NR' <br /> VEWI NM PVC 165 15 10 4 5-15 NR' 4-165 NR' <br /> VEW2 NM PVC 465 35 10 4 15-35 NR' 125-35 NR' <br /> ' Aegis Enwournotal,Inc work plan dated February S.1993 states that typically the screen slot sue is o 020 inches and the filter pack is#3 Munterey Sand. <br /> TOC-Top of axcmg <br /> R msi-Feet relative to mean sea level <br /> NR-Not recorded. <br /> NM-Not assured <br /> I <br /> (Page 1 of 1)99 965 xts <br />