My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 4:45:55 PM
Creation date
7/24/2019 9:18:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: <br />Equipment Resolution: <br />Fill Sump # <br />Fill Sump # <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />Sump Depth: <br />Height from Tank Top to Top <br />of Highest Piping Penetration: <br />Height from Tank Top to <br />Lowest Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R): <br />Test End Time: <br />Final Reading (R,): <br />Test Duration: <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />El Pass Fail <br />El Pass <br />Fail <br />Lj Pass <br />Fail <br />Pass <br />Fail <br />Is there a sensor in the sump? <br />❑Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />Was sensor removed for <br />testing? <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No E] N/A <br />[]Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />Was sensor properly replaced <br />and verified functional after <br />testing? <br />❑Yes ❑No []N/A <br />❑Yes [—]No ❑N/A <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for <br />failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.