Laserfiche WebLink
t t U <br />AifitechPetr <br />Compliance without Compromise MAR 3 0 2012 <br />GAN JOAQUIN COUNTY <br />�3N'P';i IONP,4ENTAL <br />MONITORING SYSTEM CER-1rIB j'"AT[ON <br />A. General Information <br />P.O. Box 4208 <br />Sonora CA 95370 <br />Ca: 623541 A-Haz <br />Phone: 209-532-7320 <br />Fax: 209-533-2650 <br />mail@alltechpetro.com <br />www.alitechpetro.com <br />Facility flame: Costco # Village West Marina Date of Testing/Servicing: March 21, 2012 <br />Facility Address:6649 Embarcadero, Stockton CA 95217 <br />Facility Contact Person: Mike Spence Facility Phone: (209) 951-1551 <br />LIA: San Joaquin Health; Inspector: Garrett Backus; LIA Phone: 209-468-9847; LIA Fax: 209-468-3433 <br />Make/Model of Monitoring System: Veeder-Root TLS -350i LIA Email: gbackus@sjcehd.com <br />3. Inv(?ntory of Equipment Tested/Certified: <br />Tank ID: Premium 91 Tank <br />Tank ID: Diesel Tank <br />❑In -Tank Gauging Probe. Model: None <br />❑In -Tank Gauging Probe. Model: None <br />®Annular Space Sensor. Model: 794380-344 <br />®Annular Space Sensor. Model: 794380-344 <br />®Piping Sump Sensor(s). Model: 792380-208 <br />®Piping Sump Sensor(s). Model: 792380-208 <br />❑Fill Sump Sensor(s). Model: <br />❑Fill Sump Sensor(s). Model: <br />®Mechanical Line Leak Detector. Model: VMI LD -2000 <br />®Mechanical Line Leak Detector. Model: VMI LD -2000 <br />®Tank: Overfill / High -Level Sensor. Model: Flapper Valve <br />®Tank Overfill / High -Level Sensor. Model: Flapper Valve <br />® Fillspill Bucket Tested: ®Pass ❑Fail <br />® Fillspill Bucket Tested: ®Pass ❑Fail <br />❑ Fire- extinguishers inspected and tagged: ❑OK ❑Not OK <br />❑ Fire extinguishers inspected and tagged: ❑OK []Not OK <br />Tank ID: <br />Tank ID: None <br />❑ In -Tank Gauging Probe. Model: <br />❑In -Tank Gauging Probe. Model: <br />❑Annular Space Sensor. Model: <br />❑Annular Space Sensor. Model: <br />❑ Piping Sump Sensor(s). Model: <br />[]Piping Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />[]Fill Sump Sensor(s). Model: <br />❑ Line Leak Detector. Model: <br />❑ line Leak Detector. Model: <br />❑Tank: Overfill / High -Level Sensor. Model: <br />❑Tank Overfill / High -Level Sensor. Model: <br />❑ Fillspill Bucket Tested: ❑Pass ❑Fail <br />❑ Fillspill Bucket Tested: ❑Pass ❑Fail <br />❑ Fire extin uishers inspected and tagged: ❑OK ❑Not OK <br />❑ Fire extinguishers inspected and tagged: ❑OK ❑Not OK <br />Dispenser ID: Transition Sump ® Sump: ®Dry ❑Water ❑ <br />Dispenser ID: 1 ® Sump: ®Dry ❑Water ❑Product <br />Product <br />®Dispenser Containment Sensor(s). Model: Float & Chain <br />®Dispenser Containment Sensor(s). Model: 792380-208 <br />®Shear Valve(s) (Functional test) <br />❑Shear Valve(s) (Functional test) <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />Dispenser ID: 2 ® Sump: ®Dry ❑Water ❑Product <br />Dispenser ID: 3 ® Sump: ®Dry ❑Water ❑Product <br />®Dispenser Containment Sensor(s). Model: Float & Chain <br />®Dispenser Containment Sensor(s). Model: Float & Chain <br />O Shear Valve(s) (Functional test) <br />❑ Shear Valve(s) (Functional test) <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />Dispenser ID: ❑ Sump: ❑Dry ❑Water ❑Product <br />Dispenser ID: ❑ Sump: ❑Dry ❑Water ❑Product <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑Shear Valve(s) (Functional test) <br />El Shear Valve(s) (Functional test) <br />❑ Fire extinguisher inspected and tagged: ❑OK []Not OK <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />Dispenser ID: ❑ Sump: ❑Dry ❑Water ❑Product <br />Dispenser ID: ❑ Sump: ❑Dry ❑Water ❑Product <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑Shear Valve(s) (Functional test) <br />E] Shear Valve(s) (Functional test) <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br />generating such reports, I have also attached a copy of the report; ® System set-up ® Alarm history report <br />Technician: <br />Certification: Veeder-Root 836878, Level 4 <br />ICC UST :Service Technician # 8005930 -UT <br />Date: 3/21/2012 <br />