Laserfiche WebLink
INSTRUCTIONS FOR COMPLETION OF CHAIN-OF-CUSTODY , <br /> O Y RECORD <br /> 1 Record project name and prof.r; number (include the possible Only under extremely mitigating circumstances are , <br /> appropriate subtask) in the spaces provided the samples to be held by field personnel overnight or longer <br /> 2 The personnel actually (The laboratory should be notified of the delay) <br /> sign their names in thespaces provided This l usually lnvolves 12 Under almost all circumstances, samples are required to b <br /> only one person, but if two employees are directly involved stored at 4°C from the time of sample collection Check the <br /> with the sample collection both are required to record their space provided to indicate that this procedure has been <br /> names followed Depending on specific job requirements, wherein <br /> a thermometer is used inside a transport container to monitor ' <br /> 3 It is stongly recommended that the employee(s) performing the sample storage temperature,the sampling personnel will <br /> the sample collection also complete the Cham-of-Custody record the temperature in the "Notes" section of this form <br /> Record If this is done the sampler(s)does not need to sign at the time that the sample transport container is prepared <br /> as "Recorder" in the space provided, this will be assumed for shipment Laboratory personnel will also record the <br /> But if the sampler(s) turn(s) the sample(s) over to another temperature in the "Notes" section of the "Laboratory Use ' <br /> employee who then completes the Chan-of-Custody Record, Only" section at the time of receipt <br /> the recording employee shall sign in the space provided for <br /> the recorder In addition,this transaction between sampler(s) 13 When sampling for volatile organics, check the space pro- <br /> and recorder shall be documented by the appropriate vrded if all three volatile organic analysis (VOA) orals were <br /> signatures and the time and date in the sample custody successfully filled without headspace Samples collected for ' <br /> transaction section at the bottom of this form volatile organic analysis are required to be free of bubbles <br /> This be impossible to <br /> cases <br /> 4 Each and every sample included along with the Chan-of- due toguirement gro nedwa ar aqui err characteristics <br /> har cteri tics orchieventhee use of <br /> Custody Record in the sample transport container (often a dedicated pump installations If repeated attempts at filling ' <br /> cooler)will be recorded on the record by its unique sample the VOA vial without headspace are unsuccessful,obtain the <br /> ID and the time and date of its collection This information best possible sample under the conditions In this event, do <br /> must match that on the label of the sample container(bottle, not check the space provided, instead, mark the space with <br /> brass tube, etc) The Chain-of-Custody Record, therefore, an asterisk and document the problem in the field notes and <br /> bears an exact representation of the samples that accompany in the "Notes/Miscellaneous" section at the bottom of the , <br /> it in the transport container form If field personnel receive VOA blanks from the lab with <br /> headspace (bubble[s]), this must be documented in the <br /> 5 Next to Sample ID,a sample container description code must "Notes/Miscellaneous ' section also All VOA blanks should <br /> be entered in the space provided The ' Sample Container be checked by the receiving field personnel at the time of ' <br /> Description Codes" are on the upper right of the form sample transport container receipt The presence of VOA <br /> headspace will of course be noted by the I,�tboratory for all <br /> 6 Next to the sample container description code, a sample VOA sample(s)at the time of sample receipt in the "sample <br /> description code must be entered in the space provided The condition upon receipt ' section <br /> "Sample Description Codes" are on the upper right of the <br /> form Use the code that best describes the media sampled 14 The "Notes" section is provided to allow field personnel to <br /> Most are self-explanatory Item H for "Blank/Spike" applies elaborate on any of the instructions to the laboratory for the <br /> generally to water samples only and will be used when sub- samples submitted <br /> milting a field blank, a trip blank (commonly referred to as ' <br /> a travel blank),a cleaning blank(often referred to as a rinseae 15 Describe the method of shipment in the space provided at <br /> blank), or a spike sample This code enables the laboratory the lower left Provide the name of the courier and the type <br /> to exclude this sample as a matrix-spike candidate of service requested (ie, next day air, delivery date, etc) <br /> 7 Under"Number of Containers And Preservation," the number 16 Describe the container used to transport the Cham-of-Custody ' <br /> of sample containers will be entered according to the preser- Record and its samples If a cooler,briefly describe it by noting <br /> vative added to the bottles in the field or by the laboratory distinguishing outer markings If necessary, mark the cooler <br /> before use in the field For instance, a "3" will be entered yourself with a number, etc <br /> in the "Unpreserved" box if three volatile organic analysis ' <br /> (VOA) vials are submitted with this record for EPA Method 17 If Chain-of-Custody Records other than the one being filled <br /> 601 analysis For a brass tube with soil, a "i" in this box will out are to be included in the transport container, their serial <br /> suffice numbers should be noted in the space provided This allows <br /> proper documentation of which samples are traveling together ' <br /> 8 Check the"Field Filtered" box it the sample is field filtered in the same transport container This is often an important <br /> The absence of a check means no field filtration has been regulatory QA/QC requirement In addition, this procedure <br /> performed allows proper documentation of use in a transport container <br /> of ust thaone set of <br /> 9 Enter the requested EPA Method to be performed by the vvolatr eone sampl sl,beach lank more <br /> P shown Cha n-of- Custody <br /> laboratory and check off the sample(s)on which this method Record , <br /> is to be performed <br /> Comuish- <br /> 10 Enter a turnaround-time(TAT) code for each sample on the 18 ed/eclei ed signatuthe saml es,etc)yAnytime the secton samtransaionples al d their <br /> form "TAT Codes"are in the upper-right corner of the form Chain-of-Custody Record(s) change hands <br /> The sampler/recorder must ascertain standard turnaround among <br /> employees,this is to be recorded using the signatures of the ' <br /> time for the analytical method requested and also must con- people involved and the time and date The employee who <br /> firm that this turnaround is feasible with the laboratory and actually ships the transport container shall sign in the"Dispat- <br /> at what surcharge ched By"section and note the date and time that the samples , <br /> 11 The sampler/recorder also must ascertain the maximum are shipped <br /> holding time for the sample depending on the analysis re- 19 Be sure to specify to whom and where the sample results <br /> quested and assuming that the sample is preserved and are to go Give the name of the person who is toreceive the <br /> stored by the EPA Method protocol Very important data,check off the office in which he or she works, and note <br /> remember that the maximum holding time refers to the time whether or not preliminary verbals are requested <br /> between sample collection and analysis,and not the time <br /> between sample receipt at the laboratory and analysis' 20 The <br /> Therefore, enter the sample holding time in the space yellow and pink copses of the Chain-of-CustodyboratryRecord <br /> are <br /> provided and ship the sample(s)to the laboratory as soon as to be sent with the samples to the laboratory ' <br />