My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2019 8:52:05 AM
Creation date
7/24/2019 4:44:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,r 25/01,'•2007 09:05 2099519352 VILLAGE VIEST MARINA PAGE 05 <br />UNDERGROUND STORAGE TANK <br />MOMTORING PLAN - PAGE 2 <br />VI. DISPENSER MONITORING i- <br />MONITORING <br />OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING TILE FOLLOWING METHOD(5) (Check all that apply) <br />❑ 1. CONTINUOUS ELECTRONIC MONITORING OF UNDER bISPEIdSERCONTAINMEN7 (UDC) Ms= <br />PANEL MpNTIFAC"TLTRER: MSt MODEL a: <br />MSO <br />LEAK SENSOR MANUFACTURER: Ms' MODEL #(S): <br />E AND VISUAL ALARMS? a YES [3 b. NO <br />WILL DETECTION OF A LEAK INTO THE UDC TIUGGER AUDIBL❑ M55. <br />❑ a. YES E] b. NO � <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? Msr <br />WILL FAILURE/DISCONNFCTION OF I1DC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a. YES E] b. NO <br />C6 2. MECHANICAL. ASSEMBLY (e.9- FLOAT NqDCHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK Ms9 <br />ASSEMBLY MANUFACTURER= M5e MODEL K(S); <br />11460 <br />j53.VISUAL MONTTORINGI DONE: 8 a. DAILY ❑ b. WEEKLY ("m v--7 ftw—') <br />❑ 4. NO DISPENSERS Mel <br />❑ 99, OTHER (Specify) <br />VI1. ENHANCED LEAK DETECTION M70 <br />❑ 1, WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK <br />DETECTION (BLD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §26A4 1, ELD 1S PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. TRAINING <br />MBO. <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that Vpply) <br />I. TRIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. OPERATING MANUALS FOR ELECTRONIC MONFFORJN(] EQUIPMENT (Required) <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required n of 1161nAo'3) <br />4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5, ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />ti. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICA77ON: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION' <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL 'rANK GAUGING FOR SMALL.. UNDERGROUND STORAGE TANKS- Met <br />99. ❑ OTHER (Specify): <br />personml with UST monitoring responsibilities ate familiar with all of the above documents relevant DD their job denies and can access those documents when needed. <br />By January 1, 2005 this facility will have a -Designated UST Operator" who has passed the operator erram administered by the ltttemationa) Lode COUmil (ICC). By <br />January I. 2005. and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems. <br />This training will include, but is not limited to, the fallowiri& <br />➢ Operation of the UST systems in it manner consistent with the facility's best management prac[lM <br />• The facility employee's role with regard to the leak detection equipment. <br />Y The facility employee's role with regard to spills and overfills, <br />D Wbom to contact for emcrgencm5 and leak detection alarms. <br />For facility employees hired on or after January 1, 2005, the initial training will be conducted within 30 days of the date of hire. <br />IX. COMM ENT&ADDITIONAL INFORMATION <br />dotal UST sy5tcm monitoring -related information (e.g,, additional information required by your local agency):9 FIT FIT C, g ?o <br />M2.1. <br />pies se use this section to include any ace <br />MliGK FLAPPI t2 <br />X. PERSONNEL RESPONSIBILITIES <br />AS OF I/I/O5, TTIE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPI.ICAIiON - <br />FACILITY FORM WILL 14AVF ULTIMATE AUTHORITY FOR PERFORMTNG THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br />WUIPMFNT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br />UST SYSTEMS IN ACCORDANCE WITH 23 CCR §2715 b . <br />XI- OWNER/OPERATOR SIGNATiTRE <br />CERTIFICATION: I certi that the information provided herein is true and accurate to the best of ny knowledge. Mat <br />OWKER/OPERATOR SIG IATURE DATE: <br />Owner. <br />OperAoor <br />M93, <br />OWNERIOPI?RAT NAME (print): "f92 OWNER/OPERATOR TITLE: <br />(Ag6rcy Use Only) This plan has been reviewed and: Approved ❑ Approved With Conditions ❑ Disapproved <br />I. al Agency Signature __. Date. <br />CommentV$peCial Conditions:..._.-- <br />07/23/03 <br />SJCMD-d (0743) - 314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.