My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2019 8:52:05 AM
Creation date
7/24/2019 4:44:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SUMP TESTING <br />Test Method Developed By: ❑ Piping Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />® Other (Specify) Caldwell Sump Tester <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Sump Tester Equipment Resolution: 0.005 inches in 1/2 <br />Sump # 91 Sump # Red Diesel <br />Sump # Transition <br />16:45 <br />Sump Diameter: <br />44 inches <br />44 inches <br />44 inches <br />2nd Ring <br />Sump Depth: <br />30 inches <br />30 inches <br />54 inches <br />17:15 <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />2"d Ring <br />Height from Tank Top to Top of <br />12 inches <br />12 inches <br />46 inches <br />30 minutes <br />Highest Piping Penetration: <br />Change in Reading (RF-Ri): <br />0 change <br />0 change <br />Height from Tank Top to Lowest <br />10 inches <br />10 inches <br />40 inches <br />0.005 inches in 1/2 <br />hour <br />Electrical Penetration: <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />Dry w/small amount <br />Dry w/small amount <br />Dry w/small amount <br />®Yes ❑No ❑N/A <br />Condition of sump prior to testing: <br />of dirt on bottom of <br />of dirt on bottom of <br />of dirt on bottom of <br />®Yes ❑No ❑N/A <br />®Yes ❑No ❑N/A <br />sump <br />sump <br />sum <br />Portion of Sump Tested <br />14 inches <br />14 inches <br />14 inches <br />Does turbine shut down when <br />0 Yes LJ NoLJ NA <br />Eyes LJNoLJ NA <br />NYes LJNoLJ NA <br />❑ Yes ❑ No[] NA <br />sump sensor detects liquid <br />Turbine shutdown response time <br />15 seconds <br />15 seconds <br />15 seconds <br />Is system programmed for fail-safe <br />N Yes LJ NoLJ NA <br />Yes=NoLJ NA <br />NYes LJNoLJ NA <br />❑ Yes ❑ NoLl NA <br />shutdown <br />Was fail-safe verified to be <br />Yes No NA <br />Yes No NA <br />Yes No N.4 <br />Yes No NA <br />Wait time between applying <br />pressure/vacuum/water and starting 15 minutes 15 minutes 15 minutes <br />test: <br />Test Start Time: <br />17:30 <br />16:45 <br />16:00 <br />Initial Reading (Ri): <br />2nd Ring <br />2nd Ring <br />2nd Ring <br />Test End Time: <br />18:00 <br />17:15 <br />16:30 <br />Final Reading (RF): <br />2nd Ring <br />2"d Ring <br />2"d Ring <br />Test Duration: <br />30 minutes <br />30 minutes <br />30 minutes <br />Change in Reading (RF-Ri): <br />0 change <br />0 change <br />0 Change <br />Pass/Fail Threshold or Criteria: <br />0.005 inches in 1/2 <br />hour <br />0.005 inches in 1/2 <br />hour <br />0.005 inches in 1/2 <br />hour <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing'? <br />®Yes ❑No ❑N/A <br />®Yes ❑No ❑N/A <br />®Yes ❑No ❑N/A <br />❑Yes []No ON,A <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑No ❑N/A <br />®Yes ❑No ❑N/A <br />®Yes ❑No ❑N/A <br />Dyes ❑No ❑N/A <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.