Laserfiche WebLink
Jun 09 03 11 : 39a Mike Dotten 209-533-2650 P. 1 <br /> AlItec <br /> 1.7759 Buttercup Circle, Sonora, CA 95370 . <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> alltech@getrocket.com <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Village West Marina Date of Testing/Servicing:June 5,2003 <br /> Facility Address: 6649 Embarcadero Drive,Stockton CA 95217 <br /> Facility Contact Person: Mike Spence Contact Phone No.: 209-951-1551 <br /> Make/Model of Monitoring System:Veeder-Root TLS 3501 <br /> B. Invento of Equipment Tested/Certified: <br /> Tank ID:Regular Tank Tank ID:Diesel Tank <br /> ❑In-Tank Gauging Probe, Model:None ❑In-'rank Gauging Probe. Model:None <br /> ®Annular Space or Vault Sensor. Model:Float Switch ®Annular Space or Vault Sensor. Model:Float Switch <br /> ®Piping Sump/Trench Sensor(s). Model:Float Switch ®Piping Sump/Trench Sensor(s). Model:Float Switch <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model:Red Jacket ®Mechanical Line Leak Detector, Model:Red Jacket <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:Drop Tube E Tank Overfill/High-Level Sensor. !Model:Drop Tube <br /> ❑Other ❑Other <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Pi I I Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other ❑Other <br /> Dispenser ID: I ❑Sump:❑Dry❑Water❑Product Dispenser ID:2❑ Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ❑Dis enser Containment Float(s)and Chain(s). ❑Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: ❑Sump:[]Dry[]Water❑Product Dispenser 1D: ❑ Sump:❑Dry❑Water[]Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dis enser Containment Floats and Chain(s). <br /> Dispenser ID: ❑Sump:[]Dry❑Water❑Product Dispenser ID: ❑ Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑ <br /> Dispenser Containment Float(s)and Chain (s). ❑Dis enser Containment Floats and Chain(s). <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g.manufacturers'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all Thal apply): [I System set-up [I Alarm history report <br /> Technician: 1/a& Mike Dotten,California Contractor License.No.:623541 <br /> Certification: Veeder-Root:341-32-6743;Level 3. <br /> Page 1 of 3 03101 <br />