Laserfiche WebLink
3. Company Health and Safety Coordinator <br /> Name: Ray Kablanow <br /> Phone No: (209)538-6424 <br /> ' 2.0 QUALITY ASSURANCE PROGRAM <br /> The following measures will be taken by Geological Technics Inc.to ensure that a high quality study <br /> ' is conducted and that cross contamination does not occur. <br /> 2.1 Equipment <br /> ' Soil borings may be drilled with a hollow stem continuous flight auger,owned and operated by a <br /> licensed well driller. Soil samples may be collected using a 2 inch(i.d.)modified California split <br /> ' spoon sampler,or continuous coring device,lined with brass sample tubes. <br /> 2.2 Boring Logs <br /> ' A detailed log will be made of each boring. The information to be noted includes: sample depths, <br /> blow counts if continuous coring devise is not used,horizons of detectable contamination (detected <br /> by field methods),soil classification utilizing the Unified Soil Classification System and sediment <br /> ' description(color,texture,composition,hardness,moisture content,and post-depositional changes <br /> that have occurred in the sediments). <br /> ' 2.3 Cross Contamination Prevention <br /> All sample equipment(split spoon sampler or core tube,brass tubes etc.)and auger(drilling rod, <br /> jr <br /> drilling bits,&auger,etc.) will be thoroughly cleaned before being used and between uses. Wash <br /> water may be containerized in DOT approved 55 gallon drums,labeled,and stored on site until <br /> their disposition can be arranged. Plastic gloves will be worn during sample collection and changed <br /> between all samples. <br /> 2.4 Chain of Custody <br /> Chain of Custody(CofC)forms are legal documents used to track the handling of samples All <br /> dates,times,persons and their companies will be listed from the time the sample is collected to its <br /> ultimate disposal. A CofC form will be filled out for all samples collected. The CofC will be tracked <br /> ' to ensure sample integrity. <br /> 2.5 Sample Analysis <br /> ' Soil samples will be analyzed for benzene, toluene,ethyl benzene and total xylenes(BTEX),EPA <br /> methods 8020 and 602,and for total volatile hydrocarbons-gasoline,EPA method 8015 modified. <br /> The analyses will be performed by Sherwood Laboratories of Hilmar.,California State Certification <br /> ' #1400. <br /> 2.6 Data Reduction <br /> Analytical data will be integrated with the geological data gathered during field investigation. <br /> Cross sections will be prepared to illustrate the stratigraphy and the distribution of soil <br /> contamination. The cross sections may be used for interpreting the extent of contamination. <br />