Laserfiche WebLink
CASTLE ANALYTICAL LABORATORY <br /> Environmental Testing Services 2333 Shuttle Drive,Atwater,CA 95301 Phone: (209)3842930 <br /> ' Certificate#2480 Fax: (209)384-1507 <br /> Geo-Phase Environmental Client Project ID:Cutter Lumber Sampled: 12-14-05 <br /> 2973 Veneman Ave.B-240 Reference Number:8807 Received: 12-16-05 <br /> Modesto,CA 95356 Sample Description:Water Extracted: 12-19-05 <br /> Attn:Steve Lankford Sample Prep/Analysis Method: EPA 5030/8015M,8020 Analyzed: 12-19-05 <br /> Lab Numbers:8807-1W,2W,3W,4W,5W Reported: 12-28-05 <br /> 1 <br /> TOTAL PETROLEUM HYDROCARBONS-GASOLINE <br /> ' WITH BTEX DISTINCTION <br /> ' ANALYTE REPORTING LIMIT SAMPLE ID SAMPLE ID SAMPLE ID SAMPLE ID SAMPLE ID <br /> MW-6 MW-7 MW-8B MW-9 MW-10 <br /> pg/L (ug/L) (}J9/L) (N9/L) (Ng/L) (Ng/L) <br /> ' BENZENE 0.50 170 11000 16000 2.4 ND <br /> TOLUENE 0.50 30 9400 7200 ND ND <br /> ETHYLBENZENE 0.50 1100 2300 2200 ND ND <br /> TOTAL XYLENES 0.50 580 15000 11000 0.59 ND <br /> GASOLINE RANGE <br /> i ' HYDROCARBONS 50 13000 95000 78000 101 110 <br /> ' Report Limit Multiplication Factor: 50 500 200 1 1, <br /> Report Limit Multiplication Factor for Benzene only: 500 <br /> Surrogate%Recovery: FID:147%/PID:1l8% FID:102%/PID:101% FID:113%1 PID:199% FID:99.5%I PID:194% FID:94.0%I PID:95.4% <br /> ' Instrument ID: VAR-GC1 VAR-GC1 VAR-GC1 VAR-GCI VAR-GC1 <br /> Analytes reported as ND were not detected or below the Practical Quantitation Limit <br /> ' Practical Quantitation Limit=Reporting Limit x Report Limit Multiplication Factor <br /> APPROVED BY: <br /> ' James C. Phillips/ aboratory Director or <br /> Clan J. Cone/L oratory Manager <br />