Bank of Stockton - Cutter Lumber Site Page 2 <br /> Quarterly Groundwater Monitoring Report <br /> Project No. 102.2 <br /> May 13, 2005 <br /> I <br /> 1n June of 2003, a pilot test of soil vapor extraction and air sparging was <br /> completed as documented in the August 1, 2003 report entitled Report, Remedial <br /> Action Pilot Test and Feasibility Study. A final corrective action plan (CAP) was <br /> approved by the San Joaquin County Department of Environmental Health. <br /> The system is designed for simultaneous soil vapor extraction and air sparging. <br /> ' At this time the system construction is complete and has been in operation since <br /> February. <br /> ' 1.2 Scope of Work <br /> The following work was completed during this round of groundwater monitoring: <br /> ' 1. The depth to groundwater was measured in all eight wells remaining on the <br /> site. <br /> 2. Groundwater monitoring included sample collection from six of the eight <br /> extant wells. <br /> i ' <br /> r <br /> i <br /> 2937 Veneman Ave.,#B240 Geo-Phase Environmental Inc. Phone (209) 569-0293 <br /> Modesto, CA 95356 Fax(209) 569-0293 <br />