Laserfiche WebLink
ANALYSTS OF VACUUM DISSIPATION DATA FROM PILOT TEST <br /> t54 . 4 INCHES APPLIED VACUUM: <br /> Monitoring Distance from Measured Vacuum <br /> Well SVE Well (ft) (inches w.c. ) log10 (Vac) <br /> * OB-1 9. 5 . 1 -38860567 <br /> OB-2 213 4 . 13 �1 <br /> OB-3 <br /> * = outlier not considered in analysis <br /> Additional data point based on applied vacuum: <br /> 10. 88 inches of water column at 0 feet from SVE well <br /> Slope = -. 087 <br /> Intercept = 6. 121 inches of water column <br /> R squared = • 829 <br /> t135. 6 INCHES APPLIED VACUUM: <br /> Monitoring Distance from Measured Vacuum <br /> Well SVE Well (ft) (inches w. c. ) log10 (Vac) <br /> * OB-1 9 . 5 . 11 -. 9586073 <br /> OB--2 13 . 07 -1. 154902 <br /> OB-3 24 . 1 -1 <br /> * = outlier not considered in analysis <br /> Additional data ppoint based on applied vacuum: <br /> 27 . 12 inches of water column at 0 feet from SVE well <br /> Slope = -. 104 <br /> Intercept = 11.119 inches of water column <br /> R squared = .745 <br /> t� 163 . 1 INCHES APPLIED VACUUM: <br /> Monitoring Distance from Measured Vacuum <br /> Well SVE Well (ft) (inches w.c. ) log10 (Vac) <br />! * OB-1 9 . 5 . 25 -. 60206 <br /> OB-2 . 32 -. 49485 <br /> OB-3 24 . 32 -. 49485 <br /> t * = outlier not considered in analysis <br /> Additional datapoint based on applied vacuum: <br /> 32 . 62 inches of water column at 0 feet from SVE well <br /> Slope = -. 086 <br /> Intercept = 17 .095 inches of water column <br /> R squared - •79 <br /> Average slope from tests at 3 applied vacuums = 9 . 250472E-02 <br /> 1 <br /> i <br /> 1 <br />