ARCHIVED REPORTS XR0009552
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
4004
>
3500 - Local Oversight Program
>
PR0544711
>
ARCHIVED REPORTS XR0009552
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2019 3:34:50 PM
Creation date
7/30/2019 2:52:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009552
RECORD_ID
PR0544711
PE
3528
FACILITY_ID
FA0005478
FACILITY_NAME
CUTTER LUMBER
STREET_NUMBER
4004
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17525005
CURRENT_STATUS
02
SITE_LOCATION
4004 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+� Former Manna Pro Site Page 3 <br /> Quarterly Groundwater Monitoring Report <br /> Project No. 207.2 <br /> May s, 2006 <br /> 2.0 GROUNDWATER MONITORING <br /> The following sub-sections describe the procedures associated with the <br /> completion of groundwater monitoring and ancillary activities at the site. <br /> 2.1 Groundwater Sample Colleetion <br /> ` On March 21, 2006, Del-Tech Geotechnical Services of Oakdale, CA mobilized <br /> to the site to complete groundwater monitoring. The groundwater monitoring <br /> procedure was as follows: Upon arrival, each well was opened and the water <br /> level allowed to equilibrate. As each well was opened, and prior to taking the <br /> depth to groundwater measurement, a PID organic vapor meter was used to <br /> �. screen for VOC's in the head space of the wells which were to be sampled. The <br /> depth to groundwater was then measured by lowering an electronically <br /> actuated air / water interface detector suspended from a polyethylene <br /> measuring tape calibrated to the nearest 0.01 foot (see groundwater <br /> monitoring data sheets in Appendix B). A careful notation was made of the <br /> depth to groundwater as measured by the device. No measurable free product <br /> '-` was observed in the wells. <br /> Each well to be sampled was pumped with a Waterra pump with dedicated <br /> vinyl tubing. Well water was containerized in 55-gallon, DOT approved <br /> polyethylene drums, properly labeled, and temporarily stored on-site. The rate <br /> of well purging was monitored, and each well was purged of at least three <br /> V <br /> casing volumes or until the groundwater parameters (temperature, <br /> conductivity, and pH) stabilized indicating that water representative of actual <br /> aquifer conditions was entering the well. Groundwater parameter <br /> stabilization was characterized by three successive readings within 10 percent. <br /> After the wells recharged to at least 80 percent of their original volume, <br /> samples were collected from them using methods described below. <br /> Wells purged with a Wattera pump were sampled directly from the dedicated <br /> tubing. Before, and in between uses, all re-usable sampling equipment was <br /> washed using a portable steam cleaner. Disposable gloves were worn by the <br /> sampling technician while collecting all samples. The gloves were changed <br /> between the collection of each sample to reduce the potential for cross- <br /> contamination. <br /> V <br /> Extreme care was exercised while collecting samples to prevent agitation of <br /> the water contained in the bailer. Water samples were transferred from the <br /> bailer into 40 ml VOA vials preserved with hydrochloric (provided by the <br /> analytical laboratory). All samples were checked for head space bubbles, <br /> 2937 Veneman Ave.,#5240 Geo-Phase Environmental Inc. Phone (209) 569-0293 <br /> Modesto, CA 95356 Fax(209) 569-0293 <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.