My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0078928
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
1506
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0078928
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2019 4:57:29 PM
Creation date
7/30/2019 4:47:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0078928
PE
4215
STREET_NUMBER
1506
Direction
S
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17302012
ENTERED_DATE
3/30/2018 12:00:00 AM
SITE_LOCATION
1506 S MARIPOSA RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Guidelines for field mounting of floats in Liberty EPS Systems <br /> Jr GR-Series Quick Disconnect Assembly <br /> G R20, GR22, and GR30 Assembly Engineered Pump Systems(EPS'by <br /> Liberty typically inclulu 3de a 3 float control <br /> The GR20,GR22 and GR30 quick disconnect assembly provided with your EPS system is designed to allow easy p panel In either a simplex or duplex <br /> Installation and removal of the pump.When Installed correctly it will seal and provide a means to lift the pump without configuration.(4 Float systems have <br /> disconnecting any of the discharge piping.Please ensure that installation is done as per the diagrams below. different height settings.) <br /> f <br /> Correct height settings for each float are <br /> tr I critical for proper pump cycling and <br /> ENSURE THAT operation of the alarm system. <br /> GROMMET 1S <br /> PROPERLY --- - 8. <br /> Since EPS basin heights vary with each <br /> INSTALLED system,use the centerline of the Inlet hub <br /> as the baseline for measuring the distance <br /> �q of the top two floats("Alarm"float and"On"float). <br /> The lowest float("Off'float)is measured from <br /> t'' the basin bottom. <br /> —� Note:All distances shown are measured to <br /> the center of the float cord at the attachment <br /> point on the float tree. <br /> Settings for maximum oer-cycle volume: <br /> First determine your inlet height. <br /> G R20 GR22 GR30 1.)Alarm Float(highest float)9"from centerline of inlet to float cord. <br /> ! 2.) On Float(middle float)15"from centerline of inlet to float cord. <br /> 3.) Off Float(lowest float)13"from bottom of basin to float cord. <br /> Notes for adjusting these levels: <br /> I, t <br /> 1.) Do not raise the alarm float higher than 9"below the inlet centerline or fluid will start <br /> j t backing up the inlet line prior to alarm activation. <br /> " 2.) Do not lower the"off'float below the 13"minimum.Pump shutoff needs to occur <br /> r. while the impeller is still submersed In fluid to prevent air entering the impeller cavity. <br /> I l 3.) Maintain at least a 6"minimum differential between the bottom of the"Alarm"float <br /> and the bottom of the"On"float. <br /> ENSURE THAT 4.)The"On"float can be lowered or the"Off'float raised to reduce the volume per pump cycle. <br /> RUBBER 5.)We do not recommend adjustments of more than 3"In either direction--please call the <br /> GROMMET IS Factory if you need to adjust the pump cycle beyond this recommended level. <br /> i PROPERLY <br /> INSTALLED HERE <br /> ®Copyright 2016 Liberty Pumps Inc. All rights reserved q ©Copyright 2016 Liberty Pumps Inc. All rights reserved I 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.