122 6A <br /> MODEL 122 <br /> ALARMPACKAGE <br /> ® 0 =select options or no alarm package <br /> 1 =alarm package(includes test/normal/silence switch,fuse,red light,&horn) <br /> _ ENCLOSURERATING I <br /> ® I =Indoor,NEMA 1(metal) <br /> W =Weatherproof,NEMA4X(engineered thermoplastic) <br /> STARTING DEVICE <br /> ® 1 =magnetic motor contactor 1 20/208/240V <br /> 9 =magnetic motor contactor 1 20V only <br /> PUMP FULL LOAD AMPS <br /> 0 =0-7 F LA <br /> 1 =7-15 FLA <br /> 2 =15-20 FLA <br /> 3 =20-30 FLA <br /> PUMP DISCONNECTS <br /> 0 =no pump disconnect <br /> 4 =circuit breaker 120V(select STARTING DEVICE option 9 above) <br /> 120/208/240V(select STARTING DEVICE option 1 above) <br /> FLOAT SWITCH APPLICATION <br /> H or L=pump down or pump up(select 17 option) <br /> X=no floats <br /> OPTIONS Listed below <br /> ENCLOSURE UPSIZE <br /> If you selected one or more of the * options, or two ** options, <br /> add a one-time enclosure upsize fee would apply. <br /> CODE DESCRIPTION <br /> 0 1A Red beacon only / no audio CODE DESCRIPTION <br /> (must select "0"for alarm package) Q**10K Anti-condensation heater <br /> 0 1C Horn only / no visual 0 11C NEMA 1 alarm panel <br /> (must select "0"for alarm package) 11D NEMA 4X alarm panel <br /> Q**3A Alarm flasher 14B Main disconnect (rotary style, mounted through door, non-fused) <br /> Q *3B Manual alarm reset (must select circuit breaker) <br /> Q *4A Redundant off * 0-20 FLA (total of both pumps) <br /> (select Option 4D if floats included) * 20-60 FLA (total of both pumps) <br /> 0 4B Red redundant off indicator & alarm Q 16A 10' cord in lieu of 20' (per float) <br /> (must select Option 4A also) 16B 15' cord in lieu of 20' (per float) <br /> 0 4D Redundant off float Q 16C 30' cord in lieu of 20' (per float) <br /> (must select 4A option) (select 17 option) ® 16D 40' cord in lieu of 20' (per float) <br /> Q *5A Thermal cutout/heat sensor auto reset Q 17A SJE SignalMaster® / pipe clamp 0 (per float) <br /> (for pumps w/thermal switch leads) 178 SJE SignalMasterO / externally weighted 0 (per float) <br /> *5E Seal failure circuit & red indicator (2 wire) 17C Sensor Float®I internally weighted A (per float) <br /> 6A Auxiliary alarm contact, form C 0 17D Sensor Float®/externally weighted A (per float) <br /> (included as standard) 17E Sensor Float®Mini/ pipe clamp A (per float) <br /> Q* 8A Elapsed time meter Q 17F Sensor Float® Mini / externally weighted ♦ (per float) <br /> 0* 8C Event (cycle) counter Q 17J Sensor Float®/pipe clamp A (per float) <br /> Q* 9_A Pump overload Q 19B Lead lag selector switch <br /> specify amperage after number 9 followed by letter "A" 19F Fourth float to separate alarm function from lag <br /> Example. 912A = 12 amp pump. 19T TOA (Test/Off/Automatic) switches and pump run lights <br /> *Q 0-25 FLA through door mounted <br /> *0 25-30 FLA 0 19U HOA (Hand/Off/Automatic) switches and pump run lights <br /> 10E Lockable latch - NEMA 4X through door mounted <br /> 10E Lockable latch - NEMA 1 0 19X Door mounted pump run indicator <br /> * 10F Lightning arrestor(select pump circuit breaker) • Mechanically-activated ♦ Mercury-activated <br /> if additional features are required,call the factory for a quote on an Engineered Custom control panel. <br /> SAMPLE <br /> MODEL 1220 4 H bA 8A�- 17A <br /> Alarm Package L�TWj <br /> Enclosure Rating <br /> Starting Device <br /> Pump Full Load Amps <br /> Pump Disconnect <br /> Float Switch Application <br /> Options: Auxiliary alarm contact, form C, <br /> Elapsed time meter, event (cycle) counter, <br /> SJE SignalMaster'O / pipe clamp <br /> ®SJE-Rhombus 09/10 <br />