Laserfiche WebLink
j 122 6A <br /> MODEL 122 <br /> ALARMPACKAGE <br /> Q0 =select options or no alarmpacka ie <br /> 1 =alarm package(includestest/normal/silence switch,fuse,red light,&horn) <br /> _ ENCLOSURERATING I <br /> ® I =Indoor,NEMA 1(metal) <br /> W =Weatherproof,NEMA4X(engineered thermoplastic) <br /> STARTING DEVICE I <br /> 1 =magnetic motor contactor 120/208/240V <br /> 9 =magnetic motor contactor 1 20V only <br /> PUMP FULL LOAD AMPS <br /> 0 =0-7 FLA <br /> 1 =7-15 FLA <br /> 2 =15-20 FLA <br /> 3 =20-30 FLA <br /> PUMPDISCONNECTS <br /> 0 =no pump disconnect <br /> 4 =circuitbreaker 120V(select STARTING DEVICE option 9 above) <br /> 1201208/240V(select STARTING DEVICE option 1 above) <br /> FLOAT SWITCH APPLICATION <br /> H or L=pump down or pump up(select 17 option) <br /> X=no floats <br /> OPTIONS Listed below <br /> ENCLOSURE UPSIZE <br /> If you selected one or more of the *options, or two ** options, <br /> add a one-time enclosure upsize fee would apply. <br /> CODE DESCRIPTION <br /> Q <br /> 1A Red beacon only / no audio CODE DESCRIPTION <br /> (must select "0"for alarm package) Qit#10K Anti-condensation heater <br /> 0 1C Hom only I no visual Q 11C NEMA 1 alarm panel <br /> (must select "0"for alarm package) Q 110 NEMA 4X alarm panel <br /> Q**3A Alarm flasher Q* 14B Main disconnect (rotary style, mounted through door, non-fused) <br /> Q * 36 Manual alarm reset (must select circuit breaker) <br /> Q *4A Redundant off * Q 0-20 FLA (total of both pumps) <br /> (select Option 4D if floats included) * Q 20-60 FLA (total of both pumps) <br /> Q 4B Red redundant off indicator & alarm Q 16A 10' cord in lieu of 20' (per float) <br /> (must select Option 4A also) Q 16B 15' cord in lieu of 20' (per float) <br /> Q 4D Redundant off float Q 16C 30' cord in lieu of 20' (per Float) <br /> (must select 4A option) (select 17 option) Q 16D 40' cord in lieu of 20' (per float) <br /> Q * 5A Thermal cutout/heat sensor auto reset Q 17A SJE SignalMasterg/ pipe clamp 19 (per float) <br /> (for pumps w/thermal switch leads) Q 17B SJE SignalMasterO / externally weighted 0 (per float) <br /> * 5E Seal failure circuit & red indicator (2 wire) Q 17C Sensor Float-/ internally weighted ♦ (per float) <br /> 6A Auxiliary alarm contact, form C Q 17D Sensor Floats/ externally weighted A (per float) <br /> (included as standard) Q 17E Sensor Float's Mini I pipe clamp A (per float) <br /> Q vt 8A Elapsed time meter Q 17F Sensor Floats Mini / externally weighted A (per float) <br /> Q* 8C Event (cycle) counter Q 17J Sensor Float®I pipe clamp A (per float) <br /> Q* 9_A Pump overload Q 196 Lead lag selector switch <br /> specify amperage after number 9 followed by letter"A". Q 19F Fourth float to separate alarm function from lag <br /> Example: 912A = 12 amp pump. Q 19T TOA (Test/Off/Automatic) switches and pump run lights <br /> it Q 0-25 FLA through door mounted <br /> *Q 25-30 FLA Q 19U HOA (Hand/Off/Automatic) switches and pump run lights <br /> Q 10E Lockable latch - NEMA 4X through door mounted <br /> 0 10E Lockable latch - NEMA 1 Q 19X Door mounted pump run indicator <br /> 0# 10F Lightning arrestor(select pump circuit breaker) 0 Mechanically-activated A Mercury-activated <br /> If additional features are required, call the factory for a quote on an Engineered Custom control panel. <br /> SAMPLE <br /> MODEL F122W 9 0 4 H 6A 8AC 17A <br /> Alarm Package <br /> Enclosure Rating <br /> Starting Device <br /> Pump Full Load Amps <br /> Pump Disconnect <br /> Float Switch Application <br /> Options: Auxiliary alarm contact, form C, <br /> Elapsed time meter, event (cycle) counter, <br /> SJE SignalMaster® / pipe clamp <br /> ®SJE-Rhombus 09/10 <br />