Received on 10/23/2019 <br /> //�� SJC EHD - CR <br /> Spill Prevention, Control, and Countermeasures Plan L1 NEIL O.ANDERSON <br /> JSG Trucking Company.Acampo, CA '4 n H o A s s o c i A r e r. <br /> March 19, 2015.Terraced Project No. NA157002 •lferrecon ca v <br /> Records of certified tank inspections will be kept at the facility for at least three years and shell <br /> test comparison records will be retained for the life of the tanks, if applicable. <br /> Table 5-1 summarizes inspections and tests to be performed on bulk storage containers ("EE" <br /> indicates that an environmentally equivalent measure is implemented in place of the <br /> inspection/test, as discussed in Section 4.1 of this Plan). <br /> Table 5.1 Scope and Frequency of Bulk Storage Containers Inspections and Tests <br /> TANK 10 <br /> InspectfonfTest t-D 2-MO 3-WO <br /> Visual inspection by facility personnel (as per checklist of M M M <br /> Appendix C) At At At <br /> External inspection by certified inspector (as per STI -OPF OPT OPT <br /> Standard SP-001) °'� <br /> _ e "y '#",J r kcrf><rT <br /> Internal inspectionby certified inspector (as per STI i� &e4,..�.eJ OPT* OPT* <br /> Standard SP-001) odrrl- <br /> Tank tightness test meeting requirements of 40 CFR 280 OPT* OPT* OPT* <br /> Legend: 3 <br /> M Monthly <br /> A: Annual <br /> OPT: Optional per the Steel Tank Institute (STI) for steel, shop-buik, single-walled tanks, having <br /> less than 1,000 gallons in storage capacity and secondary containment <br /> EE: Inspection not required given use of environmentally equivalent measure(referto Section 4.1 <br /> of this Plan). <br /> *Or earlier, as recommended by the certified inspector based on findings from an external <br /> inspection if performed <br /> tlnternal inspection may be recommended by the certified inspector based on findings from the <br /> external inspection. <br /> 5.9 Heating Coils (40 CFR 112.8(c)(7)) <br /> This section is not applicable because no tanks contain internal heating coils at this facility. <br /> 5.10 Overfill Prevention Systems (40 CFR 112.8(c)(8)) <br /> Tanks are equipped with an overfill alar or a direct-reading level gauge. General secondary <br /> containment will be provided in the event of overfills, as described in this Plan. Venting capacity <br /> is suitable for the FII and withdrawal rates. Facility personnel and/or the tank truck driver will be <br /> present throughout the filling operations to monitor the product level in the tanks. Tank volumes <br /> will be observed prior to and during filling to prevent overfills. <br /> Responsive. Resourceful a Reliable 23 <br />