Page 1 of 5 <br /> I <br /> Vicki McCartney [EH] <br /> From : Vicki McCartney [EH] <br /> Sent: Friday , May 02, 2014 12:58 PM <br /> To: 'Westhoff, Brian' <br /> Cc: Gabriel Gonzalez [EH] <br /> Subject: RE: Arco 2130, Stockton Regulatory Response <br /> Good afternoon Brian , <br /> Gabe Gonzalez, the new case worker for ARCO Station No. 2130 at 7906 North EI Dorado Street in Stockton , <br /> and I visited this site on Wednesday, April 30, 2014. 1 have also discussed with Adrienne Ellsaesser, Program <br /> Coordinator, Stantec's proposals for this site submitted in Well Destruction Work Plan. <br /> The following is a list of issues concerning the work plan: <br /> 1 . Under Well Destruction Activities on page 2, second paragraph , AS-2 and AS-3 are listed twice among the <br /> fifteen wells that Stantec proposes to require a variance. <br /> 2. On page 2 of the work plan , Stantec proposes to place a mushroom cap at one foot below surface grade <br /> ((bsg) when pressure grouting MW-5 , MW-6, MW-13, MW-20, AS-2, AS-3, VW-3, VW-6 , VW-8, VW-101 <br /> VWA 1 and MW-3A/B; however, on page 3 of the work plan Stantec proposes to air knife to three feet bsg <br /> and cut off the casing at three feet bsg . There is no mention of a mushroom cap. Stantec does state that <br /> "Given the risks associated with the subsurface structures at MW-6, AS-2, AS-3, VW-3, VW-6 and VW-11 , <br /> Stantec recommends air knifing to approximately one ft bgs, and each well casing will be cut at <br /> approximately one ft bgs. The borehole locations will be backfilled and resurfaced with appropriate <br /> materials to match the existing grade." Again there is no mention of a mushroom cap. <br /> If you propose to pressure grout some of the wells, you must include forming a mushroom cap. Cutting off the <br /> casing at one foot bsg will not be deep enough to form a one-foot mushroom cap, with grout six inches below and <br /> six inches above the cut-off casing. I suggest that you propose hand digging to two feet bsg , cut off the casing at <br /> 1 .5 feet bsg , form a mushroom cap from two to one foot bsg , and finish off the last foot bsg with appropriate <br /> materials to match the existing grade. <br /> am waiting to hear from Nuel Henderson as to whether MW-14, MW-19 and MW-21 should be pressure grouted <br /> or over-drilled. Since diesel was found in soil when installing these three wells, I believe that these wells should <br /> be over-drilled. Once Nuel has commented about these three wells, I will let you know. <br /> In conclusion, our agency will allow variances to pressure grout wells in or near the USTs, product lines, electrical <br /> lines and near the Healy tank. However, the work plan in its current version will not be acceptable and must be <br /> revised . <br /> Please contact me if you have any questions concerning this email. <br /> Thank you Brian . <br /> Vicki McCartney, Senior REHS <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton, California 95205 <br /> Phone: (209) 468-9852 <br /> Email: vmccartneV(a)sicehd .com <br /> 5/2/2014 <br />