Laserfiche WebLink
i <br /> MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> CHECK FOR FLOATING PRODUCT <br /> ygS NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION <br /> DO NOT SAMPLE WELL FOR P= it rzh x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS where <br /> P=calculated purge volume(gallons) <br /> n=314 <br /> r=radius of well casing in feet <br /> h=height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMITS THE CALCULATED PURGE VOLUME WHILE <br /> MONITORING GROUNDWATER <br /> OF DRYNESS BEFORE REMOVING STABILIZATION INDICATOR PARAMETERS <br /> CALCULATED PURGE VOLUME <br /> (pH, CONDUCTIVITY, TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME <br /> NO EYES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA WELL RECHARGES TO A LEVEL <br /> P14 =t 0 1 pH units SUFFICIENT FOR SAMPLE <br /> COND =± 10 % COLLECTION WITHIN 24 HOURS <br /> TEMP =t 10 OF OF EVACUATION TO DRYNESS <br /> YES NO YES NO <br /> WELL PURGING CONTINUE PURGING,EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING <br /> STABILITY SAMPLING �2) <br /> FIGURE <br /> INTERNATIONAL <br /> TECHNOLOGY MONITORING WELL PURGING PROTOCOL A-1 <br /> CORPORATION <br />