My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0009981
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2900 - Site Mitigation Program
>
PR0540858
>
ARCHIVED REPORTS XR0009981
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2019 12:56:52 PM
Creation date
8/1/2019 11:08:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009981
RECORD_ID
PR0540858
PE
2960
FACILITY_ID
FA0023360
FACILITY_NAME
ARCO SERVICE STATION #2130
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. Documentation of analytical and QC methodology (QC methodology includes use <br /> of spiked samples, duplicate samples, split samples, use of reference blanks, and <br /> check standards to check method accuracy and precision) <br /> -Field Quality Assurance <br /> • Documentation of sample preservation and transportation <br /> • Documentation of field instrument calibration and irregularities in performance <br /> Internal laboratory quality assurance checks will be the responsibility of the contract <br /> laboratories Data and reports submitted by field personnel and the contract laboratory <br /> will be reviewed and maintained in the project files <br /> Tvpes of Quality Control Checks <br /> Standard contract laboratory Quality Control may include analysis or use of the <br /> following <br /> • Method blanks — reagent water used to prepare calibration standards, spike <br /> solutions, etc is analyzed in the same manner as the sample to demonstrate that <br /> analytical interferences are under control <br /> • Matrix spiked samples — a known amount of spike solution containing selected <br /> constituents is added to the sample at concentrations at which the accuracy of the <br /> analytical method is to satisfactorily monitor and evaluate laboratory data quality <br /> • Split samples -- a sample is split into two separate aliquots before analysis to <br /> assess the reproducibility of the analysis <br /> • Surrogate samples — samples are spiked with surrogate constituents at known <br /> concentrations to monitor both the performance of the analytical system and the <br /> effectiveness of the method in dealing with the sample matrix <br /> • Control charts — graphical presentation of spike or split sample results used to <br /> track the accuracy or precision of the analysis <br /> • Quality control check samples — when spiked sample analysis indicates atypical <br /> instrument performance, a quality check sample, which is prepared independently <br /> of the calibration standards and contains the constituents of interest, is analyzed to <br /> confirm that measurements were performed accurately <br /> • Calibration standards and devices — traceable standards or devices to set <br /> instrument response so that sample analysis results represent the absolute <br /> concentration of the constituent <br />
The URL can be used to link to this page
Your browser does not support the video tag.