SANJ Q A Q U I N Environmental Health Department <br /> C: OuNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Oat-. <br /> J& L MARKET 8115 S EL DORADO ST FRENCH CAMP Jul 31 2019 <br /> Other Violations <br /> 4010 See below Unlisted AdminlstrationlDocumentation violation .V .R .COS <br /> 4020 See below Unlisted Training violation In In In COS <br /> 4030 See bel ow un listed OperationarMaintenance vl cation 0V 0R OCOS <br /> 4000 See below Unlisted ReleaseJLeakii ills violation In In In COS <br /> 4050 See below Unlisted Abandonmendillegal Dlsposallunauthorized Treatment violation .V .R .COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item N Remarks <br /> 618 CFR 112.7(e),112.8(c)(6)Failed to keep records of procedures,inspections,or integrity tests for three years. <br /> Copies of inspection and testing records were not found on site. Inspections and tests must be conducted in <br /> accordance with the written procedures developed in the Spill Prevention,Control, and Countermeasure(SPCC)Plan. <br /> The SPCC plan references SP-001 standards. Records of these inspections and tests must be signed by the <br /> appropriate supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately <br /> locate a copy of all inspection and testing records for the last three years,maintain them on site, and submit copies <br /> to the EH D. <br /> This is a repeat violation,Class If. <br /> 706 CFR 112.8(cx2)Failed to provide and maintain adequate secondary containment. <br /> The 10,000 gallon diesel tank was observed with insufficient secondary containment. Per a Professional Engineer <br /> certified secondary containment calculations dated 08/09/2011 the secondary containment for the 10,000 tank only <br /> holds 6,942 gallons.This does not provide secondary containment for the entire capacity of the tank and sufficient <br /> freeboard to contain precipitation. All bulk storage tanks must be provided with a secondary means of containment for <br /> the entire capacity of the tank and sufficient freeboard to contain precipitation. Immediately provide sufficient <br /> secondary containment for this and all other tanks at this facility. <br /> This is a repeat violation,Class If. <br /> 712 CFR 112.8(cx6)Failed to test or inspect each container for integrity based on industry standards. <br /> The SPCC plan references the STI-SPD01 industry standard.The age of the tank could not be determined and a <br /> certified STI SP-001 inspection report could not be located. Each aboveground container shall be tested and <br /> inspected for integrity on a regular schedule and whenever repairs are made. The qualifications of personnel <br /> performing tests and inspections,frequency and type of testing and inspections that take into account container size, <br /> configuration,and design shall be determined in accordance with industry standards. Examples of these integrity <br /> tests include,but are not limited to:visual inspection,hydrostatic testing, radiographic testing, ultrasonic testing, <br /> acoustic emissions testing,or other systems of non-destructive testing. Comparison records and other records of <br /> inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit a copy of <br /> the test results to the EHD,or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a repeat violation,Class If. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FM=I I0 PR05163eG SN01 071310019 <br /> EHD2e4I Rcr.0.ttr7cl Page 4 of Abaveg J Perml store,AC OR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 4840138 1 www.sjoehd.com <br />