Laserfiche WebLink
. f <br /> i <br /> COA DIVONS FOR N-1141-1-0 <br /> 9. Total influent hydrinPage: 2 <br /> as gasoline and 6I69 PPMv mdhanenintion into the remediation equipment shall not exec d 1039 PPMv <br /> 10. The total effluent hydrocarbon aon e,, <br /> as gasolirx and 617 PFMv as methane. tion from the remediation equipment shall not excead 104 PPMv <br /> 11. The heating value of the gasoline vapors and supplemental propane fuel shall not exceed 275,000 137'U/hr. <br /> 12. This equipment shall be utilized only on gasoline contaminated soil. <br /> 13. The overall hydrocarbon destruction efficiency shall not be Iess than 90% by weight at any dM. <br /> 14. The District shall be notified at least 90 days before the aquipment is to be aperatad within 1000 R. <br /> of tht outer boutfdary of a k-12 school. After appropriate public notice the APCO will deurmine <br /> whethex the equipment may operate at that location. <br /> 1S. <br /> relocated. s1�11 wed of a new location of the eqr pment at Ieast ten days bcfone it is <br /> 16. A quarter report of the equipment operation shall be submitted to the District. 17 is report shall <br /> inc udc in stent and effluent H��contrations� destxvcdon efficiency, running time, fuel usage, <br /> and daily VOC emissions (lblda <br />