07/16/96 <br /> QUALITY CONTROL REPORT DHS Certification #1400 <br /> Volatile Analyses <br /> Client: Horizon Environmental Date Received: 07/11/96 <br /> PO Box 5263 Date Started: . 07/12/96 <br /> Bakersfield, CA 93308 Date Complete: 07/16/96 <br /> ATTN: Dayne Frary <br /> Lab Report#: H6071102 Lab Sample#s PH6071113-1115 <br /> Linearity Check: <br /> BTEX Benzene 0.9997 TPH Gasoline 0.9997 <br /> Toluene 0L9997 TPH Diesel N/A <br /> Ethyl Benzene 0.9999 Motor Oil N/A <br /> Xylenes 0.9999 TRPH (418.1) N/A <br /> MTBE N/A <br /> Std % Repeatability MTBE Benzene Toluene Eth Benz Xylenes <br /> 9170( NIA 104 103 112 102 <br /> TPH Gasoline 100 TPH Diesel N/A <br /> TRPH (418.1) N/A TPH Motor Oil N/A <br /> Matrix Spike Recoveries MS MSD RPD <br /> MTBE N/A N/A ERR <br /> BTEX Benzene 108.0 104.0 3.8 <br /> Toluene 108.0 111.0 2.7 <br /> Ethyl Benzene 116.0 109.0 6.2 <br /> Xylenes 102.0 102.0 0.0 <br /> TPH Gasoline 95.0 91.0 4,3 <br /> TPH Diesel N/A N/A <br /> TRPH 418.1 N/A <br /> Method Blank MTBE Benzene Toluene Eth Benz Xylenee <br /> BTEX N/A <.3 ug/L <.3 ug/L <.3 ug/L <.3 ug/l. <br /> TPH Gasoline <50 ug/L TPH Diesel/MO NIA TRPH(418.1) N/A <br /> EPA Performance Acceptance Range <br /> Lab Control Sample% Recovery <br /> 13TEX Benzene 103 37.0 - 151.0 <br /> Toluene 94 47.0 - 150.0 <br /> Ethyl Benz 105 36.9 - 162.0 <br /> Xylenes 112 42.7 - 137.9 <br /> TPH Gasoline 104 35.0 - 130.1 <br /> TPH Diesel N/A 45.1 - 135.2 <br /> TRPH (418.1) N/A N/A <br /> Gloria Poling, Lab Director <br />