My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0010940
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ENTERPRISE
>
355
>
3500 - Local Oversight Program
>
PR0544728
>
ARCHIVED REPORTS XR0010940
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2019 5:02:14 PM
Creation date
8/1/2019 4:43:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010940
RECORD_ID
PR0544728
PE
3528
FACILITY_ID
FA0003802
FACILITY_NAME
ACCURATE DELIVERY SYSTEMS
STREET_NUMBER
355
STREET_NAME
ENTERPRISE
STREET_TYPE
PL
City
TRACY
Zip
95304
APN
21221008
CURRENT_STATUS
02
SITE_LOCATION
355 ENTERPRISE PL
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x Quarterly Report - Third Quarter 2002 <br /> ENTERPRISE INVESTMENTS (Former J.B. Murphy Trucking) <br /> 355 Enterprise Place, Tracy, California <br /> 1.0. INTRODUCTION <br /> At the request of Mr. Monty Warren-of Enterprise Investments,Advanced GeoEnvironmental,Inc. <br /> (AGE) has prepared this quarterly report for 355 Enterprise Place, Tracy, California. The site and <br /> the surrounding area are illustrated on Figure 1. Structures,boring and well locations are illustrated <br /> { on Figure 2. Background information is summarized in the AGE-prepared Monitoring,Well <br /> Installation Work Plan -November 2000, dated 27 November 2000. <br /> 2.0. PROCEDURES <br /> Five ground water monitoring wells (MW1 through MW5) and one ground water extraction well <br /> (EW 1)were monitored and sampled on 13 August 2002. Field work was performed in accordance <br /> with guidelines issued by the Central Valley Regional Water Quality Control Board(CVRWQCB) <br /> for the investigation of underground storage tanks (UST) sites. <br /> 2.1. WELL MONITORING AND EVACUATION <br /> A Solinst water level meter was used to measure the depth to ground water in the wells relative to <br /> the tops of the well casings. The ground water elevations and gradient were determined from these <br /> data(Table 1.). <br /> After recording water level measurements,disposable plastic bailers were used to purge wells MW l, <br /> `A MW3,MW4 and MW5 of standing water and a two-stage submersible pump was used to purge wells <br /> MW2 and EW 1 of standing water. Approximately 5.0 gallons of water (a minimum of 3 casing <br /> 1- ! water-volumes per well) were removed from MW 1, MW3, MW4 and MW5; approximately 12.5 <br /> gallons of water were removed from MW2; and approximately 56 gallons of water were removed <br /> from EW L Ground water temperature, pH and conductivity were measured at regular intervals <br /> during-purging using an Oakton water analyzer.Purged ground water was containerized in properly <br /> labeled DOT-approved model 17H 5 5-gallon drums and was stored on-site.Field sheets and data are <br /> included in Appendix A. <br /> 2.2. COLLECTION OF GROUND WATER SAMPLES <br /> Water samples were collected from the purged wells using new disposable plastic bailers after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume. Each water <br /> sample was.transferred into three 40-m1 VOA vials containing 0.5 ml 18% hydrochloric acid as a <br /> s sample preservative and into one 1-liter amber bottle without sample preservative.After collection, <br /> i <br /> Advanced CeoEnvironmental,Inc. <br /> j <br />
The URL can be used to link to this page
Your browser does not support the video tag.