My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 11:51:06 AM
Creation date
8/5/2019 9:15:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software Version Installed: 334.00 <br />Complete the following checklist: <br />rh" F <br />9 ` It �.3Tiy <br />SEP 2 2 2017 <br />ENVIRONMENTAL WEALTH <br />• Yes <br />(' No* <br />Is the audible alarm operational? DE <br />• Yes <br />(' No* <br />Is the visual alarm operational? <br />(+' Yes <br />No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />t: Yes <br />�' No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with <br />heir proper operation? <br />r Yes <br />No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />f— N/A <br />f* Yes <br />No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring <br />r, N/A <br />stem detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check <br />all that apply) r Sump/Trench Sensors; P Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? i* Yes; r No <br />Yes <br />No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill <br />N/A <br />prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If <br />at what percent of tank capacity does the alarm trigger? % <br />Yes* <br />t* No <br />Nas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E below. <br />Yes* <br />r No <br />Nas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />Product; r Water. If yes, describe causes in Section E below. <br />• Yesf <br />No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />• Yes <br />i� No* <br />11s all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />SITE HAD VENT BOX WITH 208 SENSOR WAS TESTED... <br />Monitoring System Certification Page 2 of 3 12/07 <br />