My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2015 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2015 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:07:11 PM
Creation date
8/5/2019 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2016
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1399\PR0231435\2016 RETROFIT PLANS SR0074936 .PDF
QuestysFileName
2016 RETROFIT PLANS SR0074936
QuestysRecordDate
5/22/2017 9:16:03 PM
QuestysRecordID
3392977
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 1 of 1 <br /> 8.FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps r <br /> Fill Riser Containment Sumps are Present,but were Not Tested r <br /> Test Method Developed By: r- Sump Manufacturer PF Industry Standard r Professional Engineer <br /> r7 Other(Specify) <br /> Test Method Used By: r Pressure r Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: VPLT Equipment Resolution:0.00001 in. <br /> Fill Containment for Fill Containment for <br /> Tank T4 RUL-1 Tank T5 PUL- 1 <br /> Sump Diameter: 48.00 in. 48.00 in. in. in. <br /> Sump Depth: 64.00 in. 60.00 in. <br /> Height from Tank Top to Top of <br /> 26.00 27.00 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 12.00 12.00 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good Good <br /> Portion of Sump Tested 28 30 <br /> Sump Material Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min min min <br /> test <br /> Test Start Time: 09:44:00 10:59:00 <br /> Initial Reading(RI): 0.00000 in. 0.00000 in. <br /> Test End Time: 10:14:00 11:14:00 <br /> Final Reading(RF): -0.00110 in. -0.00020 in. <br /> Test Duration: 30 min 30 min <br /> Change in Reading(RF-Rt): -0.00110 in. -0.00020 in. <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/- <br /> Test Result: Pass Pass <br /> Is there a sensor in the pump? t± Yes r No (: Yes r No r Yes r No r Yes r No <br /> Does the sensor alarm when either r Yes r Nor NA G- Yes r Nor NA r Yes C Nor NA r Yes r No NA <br /> product or water is detected? <br /> Was sensor removed for testing? ro Yes r Nor NA f: Yes r Nor NA r Yes r Nor NA r Yes C No N;\ <br /> Was sensor properly replaced and (; Yes r No NA r f: Yes r No NA r r Yes r No NA r r Yes r No NA <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> inN1 i 17 <br /> J <br /> WO:2330376 <br />
The URL can be used to link to this page
Your browser does not support the video tag.