My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2010 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 3:37:10 PM
Creation date
8/5/2019 11:56:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2014
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION / TEST DATE: March 5, 2012 <br />Al. FACILITY <br />A2. OWNER <br />Name 7 -Eleven Market #2368 / Store #19976 <br />Name 7 -Eleven, Inc <br />Address 1399 N. Main Street, Manteca, CA 95336 <br />Address P.O. Box 711, Dallas, TX 75221 <br />Phone# 209-239-3252 <br />Phone# 805-523-2949 <br />Contact Stephen Boyd <br />I I Contact Stephen Boyd <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 600 E. Main Street, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified February 29, 2012 <br />Lic # 617238 A, B, Haz <br />Inspector Muniappa Naidu <br />Contact Dulcinea Covan <br />Phone# 209-468-8257 <br />Phone# 916-373-1166 <br />B. I NVE NTO RY 0 F EQU I PME NT TESTED/C ERTI FI ED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />131: TANKS <br />Tank #1 (Product): Gasoline - 87 Tank #2 (Product): Gasoline -91 <br />❑ In -Tank Gauging Probe Model: ❑ In -Tank Gauging Probe Model: <br />Annular Space or Vault Sensor Model: 0794380-303 Annular Space or Vault Sensor Model: 0794380-303 <br />Piping Sump / Trench Sensor(s) Model: 0794380-208 Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />Fill Sump Sensor(s) Model: 0794380-208 Fill Sump Sensor(s) Model: 0794380-208 <br />❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: ❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): Tank #4 (Product): _ <br />❑ In -Tank Gauging Probe Model: ❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump / Trench Sensor(s) Model: ❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: ❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br />132: DISPENSERS/UDC's <br />Dispenser # : 1-2 Dispenser # : 3-4 <br />Dispenser Containment Sensor(s) Model: 0794380-208 0 Dispenser Containment Sensor(s) Model: 0794380-208 <br />Shear Valves 0 Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing th <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply <br />■ System set-up ■ Alarm History Report <br />1 (�Q <br />�JIJpL �. Wa:-�--�- W -TON— --------_.._. _.— <br />Signature: o ENGINEERING, INC. <br />Technician / Cert #: Jessie Wadkins / B35391 5307886 -UT Date: March S, 2012 <br />[uiz wanon Engineering, Inc. <br />