My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2010 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 3:37:10 PM
Creation date
8/5/2019 11:56:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2014
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />5. SECONDARY PIPE TESTING <br />Page 1 of 1 <br />Test Method Developed By: W Piping Manufacturer r Industry Standard r Professional Engineer <br />r Other (Specify) <br />Test Method Used By: P Pressure r vacuum F Hydrostatic <br />r Other (Spec) <br />Test Equipment Used: au$e Equipment Resolution: 0 loss <br />(Tank 4 - rul) <br />STP Containment I to 1/2, <br />3/4 <br />("Tank 5 - pul) <br />STP Containment I to 1/2, <br />3/4 <br />Piping Material: <br />dw flex <br />dw flex <br />Piping Manufacturer: <br />unknown <br />unknown <br />Piping Diameter: <br />2 in. <br />2 in. <br />n. <br />in. <br />Length of Piping Run: <br />75 ft. <br />50 ft. <br />Product Stored: <br />RUL <br />PUL <br />Method and location of <br />piping -run isolation: <br />sump <br />sump <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5 min <br />5 min <br />min <br />min <br />Test Start Time: <br />12:14:00 <br />12:15:00 <br />Initial Reading (RO: <br />5.00000 PSI <br />5.00000 PSI <br />Test End Time: <br />13:14:00 <br />13:15:00 <br />Final Reading (RF): <br />5.00000 PSI <br />5.00000 PSI <br />Test Duration: <br />1 hr <br />1 hr <br />Change in Reading (RF-Ri): <br />0.00000 PSI <br />0.00000 PSI <br />Pass/Fail Threshold or <br />Criteria: <br />+/-0.00000 <br />+/-0.00000 <br />+/- <br />+/- <br />Test Result: <br />Pass <br />Pass <br />Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.