My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2010 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 3:37:10 PM
Creation date
8/5/2019 11:56:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2014
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 1 of 1 <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: r UDC Manufacturer r Industry Standard r Professional Engineer <br />r Other (Specify) <br />Test Method Used By: r Pressure r Vacuum r Hydrostatic <br />r Other (Specify) <br />Test Equipment Used:VPLT <br />Equipment Resolution: 0.00001 in. <br />UDC #1/2 <br />UDC`#3/4 <br />UDC # <br />UDC # <br />UDC Manufacturer:] <br />gilbarc0 <br />gilbarco <br />i <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />uoc Depth: i29.00 <br />29.00 <br />i <br />Height from UDC Bottom to Top of <br />Highest Piping Penetration: <br />10.00 <br />I <br />10.00 <br />i <br />1 <br />Height from UDC Bottom to Lowest <br />Electrical Penetration: + <br />3.00 <br />3.00 <br />Condition of UDC prior to testing: <br />good <br />good <br />Portion of UDC Tested' j <br />12 <br />12 <br />Does turbine shut down when UDC <br />sensor detects ugwd (both product and <br />water)?' <br />r Yes r Nor NA <br />r Yes r Nor NA <br />I <br />r Yes r No r NA <br />r Yes r Nor NA <br />Turbine shutdown response time j <br />00:00:00 sec <br />00:00:00 sec i <br />sec <br />sec <br />Is programmed for fail-safe <br />shutdown?' I <br />shutdown <br />r Yes r Nor NA <br />r Yes r No r NA <br />I <br />r Yes r Nor NA <br />r Yes r No r. NA <br />Was fall -safe verified to be operational?' <br />I <br />r Yes r Nor NA <br />r Yes r No r NA <br />r Yes r Nor NA <br />r Yes r Nor NA <br />Walt time between applying <br />pressure/vacuum/water and starting test <br />5 min <br />5 min <br />min <br />min <br />Test Start Time: <br />11:19:00 <br />11:19:00 <br />Initial Reading (RI): <br />0.00000 PSI <br />0.00000 In. <br />Test End Time: <br />11:34:00 <br />11:34:00 <br />Final Reading (RF): i <br />-0.00090 PSI <br />-0.00050 in. <br />I <br />Test Duration: <br />15 min <br />15 min <br />Change In Reading (RF -Rt) : <br />-0.00090 PSI <br />0.00050 In. <br />Pass/Fall Threshold or Criteria: <br />+/- 0.00200 <br />+/- 0.00200 <br />Test Result. , , <br />Pass <br />Pass <br />Was sensor removed for testing? <br />r Yes r Nor NA <br />r Yes r Nor NA <br />r Yes r Nor NA <br />r Yes r Nor NA <br />was sensor properly replaced and <br />! <br />verified functional after testing?r <br />............. .......... __.._._............... ... .......... ............ __...... .............i <br />Yes r Nor NA <br />.............. ............. _..... _............... __....... .............. _.................... _........ <br />r Yes r Nor NA <br />j <br />.._...................... _... _.......................................... ....__...._.._......... <br />r Yes r Nor NA <br />_......_._._.._........__.____..__...—..._.__............................ <br />r Yes r No r NA <br />............ <br />Comments ? (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (') is ?NO? or ?NA?, the <br />entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.