Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#19976 1 1399 N MAIN ST, Manteca October 13, 2014 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br /> The 87 and 91 octane spill containers failed when tested. All spill containers shall have a minimum capacity of five <br /> gallons and be capable of containing a spill or overfill until it is detected or cleaned up. The technician onsite cleaned the <br /> drain valve of the 91 octane spill container and replaced the cap of the 87 octane spill container and retested both spill <br /> containers with passing results. This is a Class II violation. <br /> 326 CCR 2635(b)(2) Overfill prevention system not present, was overridden, or failed to meet overfill requirements. <br /> The mechanical overfill prevention device on the 91 octane UST is currently overridden by the presence of a measuring <br /> stick placed in the drop tube. The stick was removed by the service technician on site. Take all necessary precautions <br /> to prevent this in the future. This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by November 13, 2014. <br /> Consent to perform the inspection, take photos and collect samples was given by Prasanth Boppama (Sam), <br /> facility manager . This facility's designated operator is Fredy Barrita (ICC expiration date: April 21, 2016) . The <br /> service technician was Jarred Cooke (ICC expiration date: April 30, 2015), who had the following manufacturer's <br /> certifications: VR- May 7, 2016 and VMI: February 10, 2015. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> ALL EHD STAFFTIMEASSOCIATED WITH PAILINGTO COMPLYB VE NOTED DATESVIALL BE BILLEDATTHE CURRENTHOURLYA <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By: Title: Date: <br /> (1-3 <br /> Inspector: ELENA MANZO Title: REHS Phone: (209) 953-7699 Date: 10/13/2014 <br /> Page 4 of 4 <br />