My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2010 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 3:37:10 PM
Creation date
8/5/2019 11:56:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2014
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />,1,'l 25 2013 <br />F. In -Tank Gauging / SIR Equipment: 17 Check this box if tank gauging is used only for inventory control. <br />r Check this box if no tank gauging or SIR L' i G IMOM 4 ENTAL <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. HEALTH DEPARTMENT <br />Complete the following checklist: <br />• Yes <br />No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />• Yes <br />r No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />• Yes <br />r No* <br />Was accuracy of system product level readings tested? <br />• Yes <br />r No* <br />Was accuracy of system water level readings tested? <br />• Yes <br />No* <br />lNere all probes reinstalled properly? <br />• Yes <br />r No* <br />ere all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): r Check this box if LLDs are not installed. <br />Complete the following checklist: <br />• Yes <br />No* <br />For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? (Check all that <br />apply) Simulated leak rate: r 3 g.p.h.; r 0.1 g.p.h; I 0.2 g.p.h. <br />N/A <br />• Yes <br />No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />• Yes <br />No* <br />Was the testing apparatus properly calibrated? <br />• Yes <br />No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />N/A <br />Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />• N/A <br />• Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />• N/A <br />• Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />l: N/A <br />Yes <br />No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />• N/A <br />• Yesr <br />No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: <br />Page 3 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.