My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
2200 - Hazardous Waste Program
>
PR0514068
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2019 10:10:59 PM
Creation date
8/6/2019 12:00:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514068
PE
2227
FACILITY_ID
FA0009865
FACILITY_NAME
KIA COUNTRY
STREET_NUMBER
1515
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21619005
CURRENT_STATUS
01
SITE_LOCATION
1515 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Large Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />KIA COUNTRY <br />1515 N MAIN ST, MANTECA <br />May 17, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS it, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />507 <br />CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br />Inspections of the hazardous waste tank system was not performed and documented. The following items are <br />required to be inspected at least daily: <br />1, overfill/spill control equipment; <br />2. aboveground portions of the tank system to detect corrosion or releases of water; <br />3. data gathered from monitoring and leak -detection equipment; <br />4. outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br />hazardous waste; <br />5. for uncovered tanks, the level of waste in the tank. <br />Immediately begin required inspections of the hazardous waste tank system, and document the items inspected. <br />Submit a copy of the inspection log for the next 30 days to the EHD. <br />This is a repeat violation, Class II. <br />512 <br />CCR 66265.192(h) Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br />A hazardous waste assessment was not seen on site for the used oil tank (500 gallons) and the used antifreeze <br />tank (200 gallons). A tank assessment is required to be done on the hazardous waste tanks mentioned above. <br />Immediately submit a copy of the tank assessment to the environmental health department for review. If one is not <br />found, get a tank assessment done on the above ground storage tanks and submit a copy to the environmental <br />health department for review. <br />This is a Class II violation. <br />601 <br />CCR 66262.34(a) Stored hazardous waste on site longer than 90 days without a permit or authorization. <br />One 5 gallon black plastic bucket containing metal shavings/fine powder was observed with an accumulation start <br />date of 10-27-2017. Facilities who generate more than 1000 kg of hazardous waste per month may store waste on <br />site up to 90 days. Immediately contact a licensed hazardous waste hauler to dispose of this waste under manifest <br />and submit a copy of the manifest to the EHD. <br />One 55 gallon black steel drum containing used absorbent and one 15 gallon black steel drum containing used <br />gasoline were observed missing the accumulation start date. <br />Since it cannot be determined how long the hazardous waste has been on site, immediately contact a licensed <br />hazardous waste hauler to dispose of this waste under manifest. Submit a copy of the manifest to the EHD within 30 <br />days. <br />This is a Class II violation. <br />FA0009865 PR0514068 SC001 0511712018 <br />EHD 22-02 Rev. 0922/16 Page 7 of 9 Large Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.