COMPLIANCE INFO 2005 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 3:13:32 AM
Creation date
8/6/2019 2:20:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
As <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />i Tanknology <br />8900 SHOAL CREEK, BUILDING 200 <br />TEST DATE: 02/14/06 <br />AUSTIN, TEXAS 78757 (512) 451-6334 WORK ORDER NUMBER: 2240385 <br />CLIENT: 7 -ELEVEN, INC. <br />SITE: 7 -ELEVEN # 19976 <br />MKT 2237 <br />TANK INFORMATION <br />Tank ID: 4 <br />Tank manifolded: NO Bottom to top fill in inches: <br />142.0 <br />Product: REG UNLEAD <br />Vent manifolded: NO Bottom to grade in inches: <br />151.0 <br />Capacity in gallons: 14,781 <br />Vapor recovery manifolded: YES Fill pipe length in inches: <br />51.4 <br />Diameter in inches: 90.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 543 <br />Overspill protection: YES Stage I vapor recovery: <br />DUAL <br />Material: DW FIBERG <br />Installed: ATG Stage II vapor recovery: <br />BALANCE <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: <br />NONE <br />LEAK DETECTOR TEST RESULTS Test method: <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />UFT/OFT: <br />Make: RED JACKET <br />Fluid volume in gallons: <br />Model: Fx1V <br />Tank water level in inches: <br />S/N; 329617605 <br />Test time: <br />NOT <br />Open time in sec: 4.00 <br />Number of thermisters: <br />TESTED <br />Holding psi: 20 NOT <br />Specific gravity: <br />Resiliency cc: 110 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 12 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: NONE <br />LINE TEST RESULTS Test type: TLD -1 <br />Test time: <br />Ullage volume: <br />Material: ENVIRON <br />Ullage pressure: <br />Diameter (in): 1.5 <br />Results: <br />Length (ft): 45.0 <br />Test psi: 5o <br />DATA FOR UTS-4T ONLY: <br />Bleedback cc: 0 <br />Time of test 1: <br />Test time (min): 60 <br />Temperature: <br />NOT <br />Start time: 09:38 NOT NOT <br />NOT <br />Flow rate (cfh): TESTED <br />End time: 10:38 TESTED TESTED <br />TESTED <br />Time of test 2: <br />Final gph: 0.000 <br />Temperature: <br />Result: PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />Time of test 3: <br />Pump make: FE PETRO <br />Temperature: <br />Flow rate (cfh): <br />Impact Valves Operational: YES <br />COMMENTS <br />COMMENTS <br />Printed 05/08/2006 08:16 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.