My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 3:13:32 AM
Creation date
8/6/2019 2:20:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB;January 2002 Page 2. <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer Industry Standard a Professional Engineer <br /> El Other (Spec) <br /> Test Method Used: F] Pressure Vacuum Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used: vp 1 t Equipment Resolution: +-.00211 <br /> Sump# 4 REG Sump# 5 PRE Sump# Sump# <br /> Sump Diameter: 48" 48" <br /> Sump Depth: 6111 51'r <br /> Sump Material: fiberglass fiberglass <br /> Height from Tank Top to Top of 15y' 1911 <br /> Highest Piping Pentration: <br /> Height from Tank Top to Lowest 4" 411 <br /> Electrical Pentration: <br /> Condition of sump prior to testing: good good <br /> Portion of Sump Tested: 1 1711 2111 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both EYesalloaN aYesalloaN ayes allo❑N ayes alloaN <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 s e c 2-5 s e c <br /> Is system programmed for fail-safe ❑ � ❑ � ❑ ❑ ❑ ❑ <br /> shutdown?* Yes N N X Yes N N Yes N N Yes No <br /> Was fail-safe verified to be ayes alloaN ayes alloaN ayes alloa <br /> operational? N E Yes alloaN <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min <br /> test: <br /> Test Start Time: 8:12 8:00 <br /> Initial Reading(R1): 0 0 <br /> Test End Time: 8:4 2 8:30 <br /> Final Reading(RF): -.0003" +.0006" <br /> Test Duration: 30min 30min <br /> Change in Reading(R F-R1 ): -.0003" +.0006" <br /> Pass/Fail Threshold or Criteria: +-.00211 —. 00211 <br /> Test Result: � Pass Fail `LJ PassEl Fail 0 Pass D Fail D Pass D Fail <br /> Was sensor removed for testing? aYesalloaNA aYesalloaNA aYesaN(CN ❑Yes alloaNA <br /> Was sensor properly replaced and fl � C X❑ � ❑ � ` J ❑ a <br /> verified functional after testing? Ye N NA Ye N NA Ye NLNA Yes N A <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO" or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.