Laserfiche WebLink
INDIVIDU <br />TEST DATE: 01/18/05 <br />CLIENT:7-ELEVEN, INC. <br />TANK INFORMATION AND <br />Z P, Tan <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />AUSTIN, TEXAS 78759 (512) 451-6334 <br />ST RESULTS <br />WORK ORDER NUMBER2234065 <br />SITE:7-ELEVEN # 19976 MKT 2237 <br />CP installed on: / / <br />COMMENTS <br />TANK TEST RESULTS Test Method:VacuTect <br />LEAK DETECTOR TEST RESULTS <br />TANK INFORMATION <br />Start (in) <br />End (in) <br />Tank ID: <br />5 <br />Tank manifolded: <br />NO <br />Bottom to top fill in inches: <br />143.0 <br />Product: <br />PREMIUM <br />Vent manifolded: <br />NO <br />Bottom to grade in inches: <br />150.0 <br />Capacity in gallons: <br />9,684 <br />Vapor recovery manifolded: <br />YES <br />Fill pipe length in inches: <br />53.2 <br />Diameter in inches: <br />90.00 <br />Overfill protection: <br />YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />356 <br />Overspill protection: <br />YES <br />Stage I vapor recovery: <br />DUAL, <br />Material: <br />DW FIBERG <br />Installed: <br />ATG <br />Stage II vapor recovery: <br />BALANCE <br />CP installed on: / / <br />COMMENTS <br />TANK TEST RESULTS Test Method:VacuTect <br />LEAK DETECTOR TEST RESULTS <br />Test method: FTA <br />Start (in) <br />End (in) <br />Dipped Water Level: <br />New/passed Failed/replaced <br />New/passed Failed/replaced <br />L.D. #1 L.D. #1 <br />L.D. #2 L.D. #2 <br />Dipped Product Level: <br />Probe Water Level: <br />Make: <br />VAPORLESS <br />Ingress Detected: Water Bubble <br />Ullage <br />Model: <br />LD2000 <br />Test time: <br />S/N: <br />UNREADABLE <br />Open time in sec: <br />s. 00 <br />Inclinometer reading: <br />Holding psi: <br />28 <br />VacuTect Test Type: NOT <br />Resiliency cc: <br />120 <br />NOT <br />VacuTect Probe Entry Point: TESTED <br />Test leak rate ml/m: <br />189.0 <br />TESTED <br />Pressure Set Point: <br />Metering psi: <br />13 <br />Tank water level in inches: <br />Calib. leak in gph: <br />3.00 <br />Water table depth in inches: <br />Results: <br />PASS <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />LINE TEST RESULTS <br />Test <br />type: TLD -1 <br />LINE A <br />B <br />C <br />D <br />Material: ENVIRON <br />Diameter (in): <br />1.5 <br />Length (ft): <br />40.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />80 <br />Test time (min): <br />70 <br />NOT <br />NOT <br />NOT <br />Start time: <br />11:47 <br />TESTED <br />TESTED <br />TESTED <br />End time: <br />12:57 <br />Final gph: <br />0.009 <br />Result: <br />PASS <br />Pump type: PRESSURE <br />Pump make: FE <br />PETRO <br />COMMENTS <br />Impact Valves Operational: YES <br />Printed 01/21/2005 09:59 <br />