FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL-03-2002 14:31 gOUTHLAND CORP NW DIU. 503 977 7711 P. 16i19 <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> Mâ˘Tamkwlogy <br /> FTEST :10/24/01 8900 SHOAL CREEK.BUILDING 200 WORK ORDER NUMBER2219064 <br /> CLIENT:7-BLEVENr ZNC- AUSTIN,TEXAS 78757(512)451-6334 SITE:7-ELEVEN # 19976 MKT 2237 <br /> 111111 111ji-Inipow om Now- <br /> Tank ID: pUL 3 Tank manifolded: No Bottom to top nil in inches: 143.0 <br /> .053 <br /> Product: PRK=UM Vent manlfolded: No Bottom to grade in inches; 153.0 <br /> .o <br /> Capacity in gallons: 91995 Vapor recovery manifolded: YES Fill pipe length In Inches: 6. <br /> Diameter In inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: D40 <br /> .0 <br /> Length in inches: 330 Oversplll protection: YES Stage I vapor recovery: <br /> UAL <br /> recovery:or II a vapor Material: DW STEEL Installed: ATO Stage p ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Start(In) End(in) Newlpassed Falladlreplacad Now/passed Falled/replacad <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.02 L.D.92 <br /> Dipped Product Level; <br /> Probe Water Level: Make: ra rsxao <br /> Model: HLD <br /> Ingress Detected: Water Bubble Ullaga SIN: 991.001.2 <br /> Test time: Open time in sec: 9.00 <br /> Inclinometer reading: Holding psi: 25 <br /> VacuTect Test Type: NOT Resiliency cc: 200 NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m; 199.0 TESTED <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib.leak in gph: 3.00 <br /> Water table depth In Inches: Results: Pass <br /> Determined by(method): <br /> Result: COMMENTS <br /> COMMENTS <br /> Material: ENV2ROar.Ex <br /> Diameter(in): 2.0 <br /> Length(ft): 45.0 <br /> Test psi: 50 <br /> 131eedback cc: 210 <br /> Test time(min): 60 NOT NOT NOT <br /> Start time: 10 t 18 TESTED TESTED TESTED <br /> End time: 11.10 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: PE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 10126/2001 18:13 <br />