My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 3:46:44 AM
Creation date
8/8/2019 2:04:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> Tanknology <br /> 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER: 2209727 <br /> TEST DATE: 08/30/99 AUSTIN,TEXAS 78757(512)451-6334 <br /> CSITE: 7-ELEVEN # 19976 <br /> CLIENT: 7-ELEVEN, INC. <br /> F�'�►N1C'`tNF£>RMAT'IfJN. <br /> ., > <br /> Tank ID: 1 Tank manifolded: No Bottom to top fill in inches: 143.0 <br /> Product: REG UNLEAD Vent manifolded: NO Bottom to grade in inches: 152.0 <br /> Capacity in gallons: 9,994 Vapor recovery manifolded: YES Fill pipe length in inches: 48.0 <br /> Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 330 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> TANK TEST-RESULTS xk Str'Met9%-:4W r :, .EAIC IIEtE £5 <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: VAPORLESS <br /> Fluid volume in gallons: Model: LD2000 <br /> Tank water level in inches: S/N: 57787 <br /> Test time: NOT Open time in sec: 4.00 <br /> Number of thermisters: TESTED Holding psi: 18 NOT <br /> Specific gravity: Resiliency cc: 340 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> 7-7 <br /> iJL1LAGE7fS7RELBst�ef7At# � SNE is 1t ' eype• " ��-8 ' e„ � <br /> 9 W . <br /> Test time: Material: ENVIROFLEx <br /> Ullage volume: Diameter(in): 2.0 <br /> Ullage pressure: Length (ft): 45.0 <br /> Results: Test psi: 50 <br /> Bleedback cc: 120 <br /> DATA FOR LITS-4T ONLY: Test time (min): 30 <br /> Test 1:Start time: 13:10 <br /> Time of test 1: Finish psi: so NOT NOT NOT <br /> Temperature: NOT Vol change cc: o TESTED TESTED TESTED <br /> Test 2:Start time: 13:20 <br /> Flow rate (cfh): TESTED Finish psi: 4e <br /> Time of test 2: Vol change cc: 13 <br /> Test 3:Start time: 13:30 <br /> Temperature: Finish psi: so <br /> Flow rate (cfh): Vol change cc: o <br /> Time of test 3: Final gph: 0.007 <br /> Temperature: Result: PASS <br /> Flow rate (cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Draft 08/31/1999 10:28 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.