My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 3:46:44 AM
Creation date
8/8/2019 2:04:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUA ANK/LINE/LEAK DETECTOR TE REPORT <br /> TANKN L Y-NDE <br /> TEST DATE: 07/27/98 WORK ORDER NUMBER: 2205319 <br /> CLIENT: THE SOUTHLAND SITE: 7-ELEVEN 19976 <br /> Tank ID:10x/92 3 Material:Dw STEEL Bottom to top fill in inches: 143.0 <br /> Product:PREMIUM Tank manifolded:NO Bottom to grade fill in inches: 153.0 <br /> Capacity in gallons: 9,994 Vent manifolded:NO Fill pipe length in inches: 48.0 <br /> Diameter in inches: 95.00 Vapor recovery manifolded:YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 330 Impact Valves Operational: Y Stage I vapor recovery: DUAL <br /> Tank age (years): Overfill protection: YES Stage II vapor recovery: ASSIST <br /> Fuel pure rating: Overspill protection: YES Installed: ATG <br /> COMMENTS CP installed on: / / <br /> TANK TEST RESULTS Test Method:VacuTect LEAK DETECTOR RESULTS Test method: <br /> Start(in) End(in) New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make:VAPORLESS <br /> Probe Water Level: Model: LD2000 <br /> Ingress Detected: Water Bubble Ullage S/N: 57786 <br /> Test time: Open time in sec: 3.00 <br /> VacuTect Test Type: Holding psi: 18 <br /> VacuTect Probe Entry Point: Resiliancy cc: 170 <br /> Pressure Set Point: Test leak rate ml/m: 189.0 <br /> Tank water level in inches: Metering psi: 10 <br /> Water table depth in inches: Calib. leak in gph: 3.00 <br /> Determined by (method): Results: PASS <br /> Result: <br /> COMMENTS COMMENTS <br /> LINE TEST RESULTS Test type: TLD-1 <br /> LINE A B C D <br /> Material: ENVIROFLEX <br /> Diameter(in): 2.0 <br /> Length (ft): 45.0 <br /> Test psi: 50 <br /> Bleedback cc: 180 <br /> Test time (min): 30 <br /> Test 1: Start time: 0 9:28 <br /> Finish psi: 50 <br /> Vol change cc: 7 <br /> Test 2: Start time: 09:38 <br /> Finish psi: 50 <br /> Vol change cc: 3 <br /> Test 3: Start time: 09:48 <br /> Finish psi: 50 <br /> Vol change cc: 0 <br /> Final gph: 0.005 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> 8900 SHOAL CREEK, BUILDING 200,AUSTIN,TEXAS 78757(512)451-6334 Draft 07/28/98 14:52 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.